We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Performance Evaluation of Fiber Near-Infrared (NIR) Optic Probes for Quality Control of Curd Hardness in Cheese Produced by Spray-Dried Milk
PeriodicalsChemistry

Performance Evaluation of Fiber Near-Infrared (NIR) Optic Probes for Quality Control of Curd Hardness in Cheese Produced by Spray-Dried Milk

Checking your access to this record.

Abstract & Overview

This study aims to provide the dairy industry with a direct control model focused on milk coagulation by using multifiber probes to determine parameters in the curding process, such as cutting time, at a lower cost. The main objective of the research is to confirm that a multifiber NIR light scattering probe can be used to predict the elastic modulus of curd during milk coagulation in cheese production. Two randomized complete block designs were used with a 3 × 3 factorial arrangement of three protein levels (3%, 3.5% and 4%) and three wavelengths (870 nm, 880 nm and 890 nm). Using a multifiber probe at a wavelength of 880 nm allowed obtaining a better optical response of the sensor during enzymatic milk coagulation than the 870 nm. It showed greater sensitivity to variations in the protein content of the milk and lower variation in the response. The multifiber probe at a wavelength of 880 nm generated a NIR light backscatter profile like those obtained with other systems. The results showed that the prediction model parameters had a variation as a function of the protein content, which opens the possibility of improving the prediction model’s performance substantially. Furthermore, the initial voltage obtained with the probe responded linearly to the different protein levels in milk. This fact would make it possible, at least theoretically, to estimate protein concentration with the same inline probe for G’ determination, facilitating the incorporation of a corrective protein factor in the prediction models using a single instrument.

Cite this record

Lesther Meza, Ricardo Santos Alemán, Jhunior Marcía, Ajitesh Yadav, Manuel Castillo (2023). Performance Evaluation of Fiber Near-Infrared (NIR) Optic Probes for Quality Control of Curd Hardness in Cheese Produced by Spray-Dried Milk. Spectroscopy Journal, 1(3), 152–162. https://doi.org/10.3390/spectroscj1030013

Copy in another style

Meza, L., Alemán, R. S., Marcía, J., Yadav, A., & Castillo, M. (2023). Performance Evaluation of Fiber Near-Infrared (NIR) Optic Probes for Quality Control of Curd Hardness in Cheese Produced by Spray-Dried Milk. Spectroscopy Journal, 1(3), 152–162. https://doi.org/10.3390/spectroscj1030013
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.