Towards clinically useful coded apertures for planar nuclear medicine imaging

Checking your access to this record.

Abstract & Overview

Coded apertures have the potential to increase imaging e ciency in nuclear medicine \nwithout degrading resolution, but near- eld artifacts are present even under idealised \naperture and imaging conditions. The purpose of this work is to reduce artifacts \nprior to reconstruction, and to work towards coded apertures that are clinically \nuseful. A ray-tracing simulator was developed. Far- eld conditions produce nearperfect \nimages, but the simulation of distributed sources under idealised near- eld \nconditions results in the presence of artifacts. \nThree core concepts are introduced in this thesis: a novel rotatable array of identical \nlimited- eld-of-view coded apertures; the use of high-resolution aperture projections; \nand the deliberate and counter-intuitive use of thin, highly transparent aperture \nmaterial. \nAn array of identical limited- eld-of-view coded apertures, which can be rotated so as \nto implement an existing artifact-reduction technique, was simulated. The artifacts \nthat exist for a single coded aperture under idealised conditions are removed. This \nnovel technique remains e ective when realistic near- eld conditions are introduced \ninto the simulation. However, realistic apertures increase artifacts due to nite \npinhole widths and nite thickness of the aperture material. To address the pinhole \nwidth problem, high-resolution patterns, in which the smallest hole corresponds to a \nprojection area of 1 1 detector pixels, o er the best trade-o between e ciency and \nresolution despite the partial volume e ect. The nite aperture thickness problem \nis addressed by another novel concept; viz. the deliberate reduction in material \nthickness, which results in a highly transparent coded aperture. Simulation shows \nthat this counter-intuitive approach diminishes collimation e ects. \nThe implementation of any or all of these three core concepts, however, reduces count \nstatistics. An ultra-near- eld geometry, which would ordinarily result in severe \nartifacts, can theoretically be used to maintain count statistics, without altering \neither patient dose or image acquisition time. This was veri ed by simulation. \nii \nABSTRACT \nA prior-state-of-the-art 1 mm thick tungsten coded aperture, and a deliberately \nhighly transparent 100 m tungsten foil coded aperture, were constructed for use \nwith a dual head gamma camera. Phantom studies of Technetium-99m point, \nline, syringe and printed distributed sources were performed. The experimental \nacquisitions veri ed the simulation results, for both the prior-state-of-the-art coded \naperture and the novel high-transparency coded aperture. \nThe results and arguments presented in this thesis point to the potential for these \nthree core developments to produce high-quality coded aperture images in a fraction \nof the time that is taken for a collimator acquisition. The limiting factor appears to \nbe the poor count statistics that result from the low sensitivity of current gamma \ncameras; a situation which looks set to change given current research trends.

Cite this record

David M. Starfield (2009). Towards clinically useful coded apertures for planar nuclear medicine imaging. Thesis, University of the Witwatersrand. https://library.shubhaarti.com/content/a7500279-8904-4cb6-9e96-ad8d4f7cc4c8

Copy in another style

Starfield, D. M. (2009). Towards clinically useful coded apertures for planar nuclear medicine imaging. Thesis, University of the Witwatersrand. https://library.shubhaarti.com/content/a7500279-8904-4cb6-9e96-ad8d4f7cc4c8