When the 2010 Maule earthquake struck central Chile, hundreds of reinforced concrete bridge piers suffered irreparable damage that took years and billions of dollars to replace. Precast segmental columns assembled from discrete concrete segments stacked with dry (ungrouted) joints and held together by unbonded post-tensioning offer a fundamentally different damage pattern: the joints open and close under lateral drift, allowing the column to rock rather than form plastic hinges, and the post-tensioning tendons pull the column back toward vertical once the lateral force is removed. This research tested six column specimens under combined constant axial load and reversed cyclic lateral displacement at the Valdivia Foundation for Structural Research, Chile. One monolithic control column (MON-1) and five segmental columns (2, 3, or 4 segments, at low or high post-tensioning levels) were loaded to 4% lateral drift. The monolithic column reached the highest peak lateral load (247.3 kN) but also the largest residual drift (1.83%). The 4-segment column with high post-tensioning (SEG-4H) achieved a residual drift of only 0.52% a 72% reduction while retaining 79.3% of the monolithic peak load and increasing displacement ductility from 4.2 to 5.4. Energy dissipation in the segmental columns was 17-29% lower than the monolithic control, a trade-off inherent in the rocking mechanism, but the self-centering ratio (defined as the ratio of recovered to peak displacement) reached 0.93 for SEG-4H compared with 0.42 for the monolithic column. A radar-chart comparison across six performance metrics confirmed that segmental columns with high post-tensioning offer the best overall balance of strength, ductility, self-centering, and damage tolerance making them a viable option for seismic regions where rapid post-earthquake return to service is a priority.

Cite this record

Osvaldo Carreño (2026). Structural behavior of precast segmental concrete columns with dry joints under combined axial and lateral loading. International Journal of Structural Design and Engineering, 7(2), 37–41. https://doi.org/10.22271/27078280.2026.v7.i2a.80

Copy in another style

Carreño, O. (2026). Structural behavior of precast segmental concrete columns with dry joints under combined axial and lateral loading. International Journal of Structural Design and Engineering, 7(2), 37–41. https://doi.org/10.22271/27078280.2026.v7.i2a.80
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.