We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations
PeriodicalsChemistry

Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations

Checking your access to this record.

Abstract & Overview

A simple, rapid and sensitive method for the determination of atorvastatin calcium in pharmaceutical preparations using two modified carbon paste electrodes was developed. One electrode (sensor A) is based on ion-pair of atorvastatin with 5,6-diaminouracil hydrochloride (ATS-DAUH) and the other (sensor B) is based on atorvastatin with picric acid (ATS-PC). Among three different solvent mediators tested, dioctylphthalate (DOPH) exhibited a proper behavior including Nernstian slopes of the calibration curve at 58.76 ± 0.8 and 57.48±1 mV per decade for sensors A and B. The response times were 10 and 12 s, detection limits 1.3 × 10 −6 and 2.2 × 10 −6 M; the concentration range 2.5 × 10 −6 -7.9 × 10 −2 M and 3.0 × 10 −6 to 7.9 × 10 −2 M respectively. The present electrodes show good discrimination of atorvastatin calcium from several inorganic, organic ions, sugars and some common excipients. The sensors were applied for the determination of atorvastatin calcium in pharmaceutical preparations using standard addition and the calibration curve methods. The results obtained were satisfactory with excellent percentage recovery comparable and sometimes better than those obtained by other routine methods for the assay. The proposed potentiometric methods offer the advantages of simplicity, accuracy, automation feasibility and applicability to turbid and colored sample solutions.

Cite this record

Salwa Fares Rassi (2017). Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations. Analytical Chemistry Research, 12, 65–73. https://doi.org/10.1016/j.ancr.2017.06.001

Copy in another style

Rassi, S. F. (2017). Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations. Analytical Chemistry Research, 12, 65–73. https://doi.org/10.1016/j.ancr.2017.06.001
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.