We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Materials Science/Comparison of Diamond‐Like‐Carbon and Alumina‐Oxide articulating with Polyethylene in Total Hip Arthroplasty
PeriodicalsMaterials Science

Comparison of Diamond‐Like‐Carbon and Alumina‐Oxide articulating with Polyethylene in Total Hip Arthroplasty

Checking your access to this record.

Abstract & Overview

To reduce wear in joint bearings of total hip arthroplasty (THA) is the most important issue for improving long term results and implant survival. Due to low wear rates and excellent tribological features in simulator tests Diamond‐Like‐Carbon coating (DLC) of femoral balls is still discussed as an alternative articulation in THA. This clinical prospective study compares survivorship of DLC‐coated femoral heads and of Aluminia‐Oxide‐ (Al 2 O 3 ) heads articulating with Polyethylene (PE). Over a period of two years 101 THA with DLC‐coated heads and PE cups (DLC‐group) and another 101 THA consisting of Al 2 O 3 heads (Al 2 O 3 ‐group) and PE cups as well were implanted. Both articulations were based on the same type of cementless hip joint prosthesis. All hips were implanted by one surgeon in consecutive series consisting of 51 Al 2 O 3 and 101 DLC‐articulations and further 50 Al 2 O 3 . All perioperative and follow‐up data was processed with SPSS®. Survival of THA in both groups was evaluated according to Kaplan‐Meier survivorship analysis with an intervall of 90 months (range:78‐101). Qualitative surface analysis was performed in nineteen retrieved DLC‐heads which were revised for aseptic loosening using field scanning electron microscopy (FE‐SEM, XL 30 SFEG Philips, Eindoven NL). 178 patients (88.2 %) were evaluated for follow‐up. Fourteen patients died meantimes (nine DLC, five Al 2 O 3 ) with the implant components not revised. Ten patients (five DLC, five Al 2 O 3 ) were lost to follow‐up. Both groups were comparable regarding patient age, weight and indications for THA with a normal distribution. Survivorship analysis for aseptic loosening 8.5 years following implantation resulted in a significant difference between both groups with a 54 % survival for DLC/PE compared to 88 % for Al 2 O 3 /PE bearings (p <0.001). No correlation to variables as age, gender or bodyweight could be detected. Surfaces of nineteen retrieved DLC‐heads showed numerous smallest pits of the diamond‐carbon layers in different quantity. SEM showed delamination of the carbon layer which caused excessive debris of polyethylene and in some cases even of the metallic substrate of the heads. Despite modern manufacturing technology and excellent experimental results for its tribochemical characteristics and wear, even “new” DLC‐coating of femoral heads is to be considered critically due to very high rates of clinical failure.

Cite this record

G. Taeger, Lars Erik Podleska, B. Schmidt, M. Ziegler, Dieter Claus Nast-Kolb (2003). Comparison of Diamond‐Like‐Carbon and Alumina‐Oxide articulating with Polyethylene in Total Hip Arthroplasty. Materialwissenschaft und Werkstofftechnik, 34(12), 1094–1100. https://doi.org/10.1002/mawe.200300717

Copy in another style

Taeger, G., Podleska, L. E., Schmidt, B., Ziegler, M., & Nast-Kolb, D. C. (2003). Comparison of Diamond‐Like‐Carbon and Alumina‐Oxide articulating with Polyethylene in Total Hip Arthroplasty. Materialwissenschaft und Werkstofftechnik, 34(12), 1094–1100. https://doi.org/10.1002/mawe.200300717
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.