We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Fire resistance tests on timber beam-to-column shear connections
PeriodicalsCivil & Construction Engineering

Fire resistance tests on timber beam-to-column shear connections

Checking your access to this record.

Abstract & Overview

Purpose This paper aims to present the results of an extensive experimental programme on the fire behaviour of timber beam-to-column shear connections, loaded perpendicularly to the grain. Design/methodology/approach The experimental programme comprised tests at normal temperature and loaded fire resistance tests on beam-to-column connections in shear. Twenty-four full-scale tests at normal temperature were performed covering nine different connection typologies, and 19 loaded fire resistance tests were conducted including 11 connections typologies. Findings The results of the fire resistance tests show that the tested typologies of steel-to-timber dowelled connections reached more than 30 and even 60 minutes of fire resistance. However, aspects such as a wider gap between the beam and the column, reduced dowel spacing, and the presence of reinforcement with self-drilling screws all have a negative influence on the fire resistance. Originality/value The experimental programme addressed the fire behaviour of timber beam-to-column shear connections loaded perpendicularly to the grain in a systematic way testing a wide range of common connection typologies significantly enlarging their experimental background.

Cite this record

Pedro Palma, Andréa Frangi, Erich Hugi, Paulo Barreto Cachim, Helena Cruz (2016). Fire resistance tests on timber beam-to-column shear connections. Journal of Structural Fire Engineering, 7(1), 41–57. https://doi.org/10.1108/jsfe-03-2016-004

Copy in another style

Palma, P., Frangi, A., Hugi, E., Cachim, P. B., & Cruz, H. (2016). Fire resistance tests on timber beam-to-column shear connections. Journal of Structural Fire Engineering, 7(1), 41–57. https://doi.org/10.1108/jsfe-03-2016-004
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.