We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electronics & Telecommunication Engineering/A 4 × 4 Biosensor Array With a 42-μW/Channel Multiplexed Current Sensitive Front-End Featuring 137-dB DR and Zeptomolar Sensitivity
PeriodicalsElectronics & Telecommunication Engineering

A 4 × 4 Biosensor Array With a 42-μW/Channel Multiplexed Current Sensitive Front-End Featuring 137-dB DR and Zeptomolar Sensitivity

Checking your access to this record.

Abstract & Overview

This paper presents a multiplexed current sensitive readout for label-free zeptomolar-sensitive detectors realized with large area Electrolyte Gated Organic Thin Film Transistors (EGOFETs). These highly capacitive biosensors are multiplexed using an OTFT line driver and OTFT switches, and interfaced to a 65-nm Si CMOS, low power, pA-sensitive front-end. The Si chip performs analogue-to-digital conversion and data transmission to a microcontroller too. A current domain interface is used to transmit the signals coming from multiple biosensors to the 1.2 V-supply CMOS Si-IC via the 30V-supply OTFT electronics. Exploiting an analogue module implemented in the Si-IC, the EGOFETs are precisely biased, even in presence of a large OTFT multiplexer resistance. The CMOS current sensitive front-end achieves a dynamic range (DR) of 137 dB and a power consumption of 42 lW per channel reaching a state-of-the-art DR-power-bandwidth FOM of 208 dB. The front-end has been designed with a first stage programmable-gain, active-feedback transimpedance amplifier topology that, contrary to common current-sensitive front-end solutions, is not affected by the sensor capacitance. The system has been validated with different concentrations of human IgG and IgM proteins using both a single sensor and a 4x4 array of EGOFETs. Thanks to the multiplexing strategy and the low-costs of its modules, the system here presented has the potential to enable widespread use of precision diagnostic with extreme sensitivity even in point-of-care and low-resource settings.

Cite this record

Enrico Genco, Marco Fattori, Pieter J. A. Harpe, Francesco Modena, Fabrizio Antonio Viola, Mario Caironi, et al. (2022). A 4 × 4 Biosensor Array With a 42-μW/Channel Multiplexed Current Sensitive Front-End Featuring 137-dB DR and Zeptomolar Sensitivity. IEEE Open Journal of the Solid-State Circuits Society, 2, 193–207. https://doi.org/10.1109/ojsscs.2022.3217231

Copy in another style

Genco, E., Fattori, M., Harpe, P. J. A., Modena, F., Viola, F. A., Caironi, M., Wheeler, M., Fichet, G., Torricelli, F., & Sarcina, L. (2022). A 4 × 4 Biosensor Array With a 42-μW/Channel Multiplexed Current Sensitive Front-End Featuring 137-dB DR and Zeptomolar Sensitivity. IEEE Open Journal of the Solid-State Circuits Society, 2, 193–207. https://doi.org/10.1109/ojsscs.2022.3217231
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.