We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biotechnology/Influence of non-ionic, ionic and lipophilic polymers on the pH and conductivity of model ointments, creams and gels
PeriodicalsBiotechnology

Influence of non-ionic, ionic and lipophilic polymers on the pH and conductivity of model ointments, creams and gels

Checking your access to this record.

Abstract & Overview

BACKGROUND: The pH of the skin surface is usually between 5.4 and 5.9 and functions as a barrier against bacteria and fungi; thus, the composition of the topically applied drug form may be of high importance for proper medication. OBJECTIVES: To evaluate the influence of the measurement conditions in aqueous solutions of ointments, creams, and gels, which include polymeric components, on the pH and conductivity results. MATERIAL AND METHODS: The pH and electrolytic conductivity of aqueous dispersions of commercially available ointments, creams and gels were tested and compared to reference vehicles. RESULTS: The results of the dilution method measurements of the pH and electrolytic conductivity of the ointment preparations are highly diverse, ranging from 5.88 to 6.27, whereas the reference pH for Unguentum simplex was between 5.40 and 5.43. Furthermore, the measurements of the pH and electrolytic conductivity with the dilution method for creams did not provide repeatable results with a small sample size, and the pH of commercial preparations was in the range between 5.79 and 6.37, compared to the reference pH of 5.23-5.46. However, the dilution method for measurements of the pH and electrolytic conductivity was suitable for hydrogel preparations and the obtained results were repeatable in the range of 6.11-6.90, while the reference preparations were in the range of 5.19-5.62. CONCLUSIONS: Evaluation methods of the electrolytic conductivity and pH of the preparations applied on the skin should be further evaluated; however, the pH of the commercial preparation seems to differ from the physiological skin pH, which covers the range of reference preparations.

Cite this record

Krause Agnieszka, Katarzyna Kucharska, Witold Musiał (2021). Influence of non-ionic, ionic and lipophilic polymers on the pH and conductivity of model ointments, creams and gels. Polymers in Medicine, 51(1), 25–32. https://doi.org/10.17219/pim/139613

Copy in another style

Agnieszka, K., Kucharska, K., & Musiał, W. (2021). Influence of non-ionic, ionic and lipophilic polymers on the pH and conductivity of model ointments, creams and gels. Polymers in Medicine, 51(1), 25–32. https://doi.org/10.17219/pim/139613
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.