We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Optimizing Momentum Resolution with a New Fitting Method for Silicon-Strip Detectors
PeriodicalsPhysics

Optimizing Momentum Resolution with a New Fitting Method for Silicon-Strip Detectors

Checking your access to this record.

Abstract & Overview

Two new fitting methods are explored for momentum reconstruction. They give a substantial increase of momentum resolution compared to standard fit. The key point is the use of a different (realistic) probability distribution for each hit (heteroscedasticity). In the first fitting method an effective variance is calculated for each hit, the second method uses the search of the maximum likelihood. The tracker model is similar to the PAMELA tracker with its two sided detectors. Here, each side is simulated as a momentum reconstruction device. One of the two is similar to silicon micro-strip detectors of large use in running experiments. The gain obtained in momentum resolution is measured as the virtual magnetic field and the virtual signal-to-noise ratio required by the standard fits to overlap with the best of the new methods. For the low noise side, the virtual magnetic field must be increased 1.5 times to reach the overlap and 1.8 for the other. For the high noise side, the increases must be 1.8 and 2.0. The signal-to-noise ratio has to be increased by 1.6 for the low noise side and 2.2 for the high noise side ( η -algorithms). Each one of our two methods shows a very rapid linear increase of the resolution with the number N of detector layers, the two standard fits have the usual slow growth less than N .

Cite this record

Gregorio Landi, Giovanni E. Landi (2018). Optimizing Momentum Resolution with a New Fitting Method for Silicon-Strip Detectors. Instruments, 2(4), 22–22. https://doi.org/10.3390/instruments2040022

Copy in another style

Landi, G., & Landi, G. E. (2018). Optimizing Momentum Resolution with a New Fitting Method for Silicon-Strip Detectors. Instruments, 2(4), 22–22. https://doi.org/10.3390/instruments2040022
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.