Diagnostic Accuracy of a Bespoke Multiorgan Ultrasound Approach in Suspected Pulmonary Embolism

Checking your access to this record.

Abstract & Overview

Purpose The aims of this study were to prospectively assess the diagnostic accuracy of a bespoke multiorgan point-of-care ultrasound approach for suspected pulmonary embolism and evaluate if this model allows reduced referral to further radiation diagnostics while maintaining safety standards. Materials and Methods Patients with suspected pulmonary embolism referred for CT pulmonary angiography or ventilation/perfusion scintigraphy were included as a convenience sample. All patients were subject to blinded ultrasound investigation with cardiac, lung, and deep venous ultrasound. The sensitivity and specificity of applied ultrasound signs and the hypothetical reduction in the need for further diagnostic workup were calculated. Results 75 patients were prospectively enrolled. The Wells score was below 2 in 48 patients, between 2 and 6 in 24 patients, and above 6 in 3 patients. The prevalence of pulmonary embolism was 28%. The most notable ultrasound signs were presence of a deep venous thrombus, at least two hypoechoic pleural-based lesions, the D-sign, the 60/60-sign, and a visible right ventricular thrombus which all had a specificity of 100%. Additionally, a multiorgan ultrasound investigation with no findings compatible with pulmonary embolism yielded a sensitivity of 95.2% (95%CI: 76.2–99.9). CT or scintigraphy could be safely avoided in 70% of cases (95%CI: 63.0–83.1%). Conclusion The findings of our study suggest that implementation of a multiorgan ultrasound assessment in patients with suspected pulmonary embolism may safely reduce the need for CT or scintigraphy by confirming or dismissing the suspicion.

Cite this record

Casper Falster, Gro Egholm, Rune Wiig Nielsen, Mikael Kjær Poulsen, Jacob Eifer Møller, Stefan Posth, et al. (2022). Diagnostic Accuracy of a Bespoke Multiorgan Ultrasound Approach in Suspected Pulmonary Embolism. Ultrasound International Open, 08(02), E59–E67. https://doi.org/10.1055/a-1971-7454

Copy in another style

Falster, C., Egholm, G., Nielsen, R. W., Poulsen, M. K., Møller, J. E., Posth, S., Brabrand, M., & Laursen, C. B. (2022). Diagnostic Accuracy of a Bespoke Multiorgan Ultrasound Approach in Suspected Pulmonary Embolism. Ultrasound International Open, 08(02), E59–E67. https://doi.org/10.1055/a-1971-7454
Author names are used as deposited, so check their order before you submit.