Abstract & Overview
Since the 1995 Hyogo-ken nanbu earthquake, there have been major changes in Japanese seismic design for bridges. These changes include the formal adoption of the ductility design method and various practices to enhance the ductility and shear capacity of reinforced concrete (RC) piers. This article presents an overview of the past and new seismic design practices for RC piers in Japanese highway bridges. The damage statistics of RC piers in the Hyogo-ken nanbu earthquake are examined and the seismic performance of RC piers designed by the pre- and post-hyogo-ken nanbu earthquake seismic design codes is evaluated.