We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation – A case study
PeriodicalsMedical Sciences

Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation – A case study

Checking your access to this record.

Abstract & Overview

PURPOSE: The treatment planning of bilateral breast irradiation (BBI) is a challenging task. The overlapping of tangential fields is usually unavoidable without compromising the target coverage. The purpose of this study was to investigate the technical feasibility and benefits of a single isocentre volumetric modulated arc therapy (VMAT) in BBI. METHODS AND MATERIALS: Two women with bilateral breast cancer were included in this case study. The first patient (Pat#1) underwent a bilateral breast-conserving surgery and sentinel lymph node biopsy. The second patient (Pat#2) underwent a bilateral ablation and axillary lymph node dissection. Planning target volumes (PTV) and organs at risk were delineated on CT images. VMAT plans were created with four (two for both sides, Pat#1) or two (one for each breast, Pat#2) separate VMAT fields. Subsequently, traditional tangential field plans were generated for each patient and the dosimetric parameters were compared. RESULTS: The treatment times of the patients with VMAT were less than 15 min with daily CBCT imaging. When compared to the standard tangential field technique, the VMAT plans improved the PTV dose coverage and dose homogeneity with improved sparing of lungs and heart. With traditional field arrangement, the overlapping of the tangential fields was inevitable without significantly compromising the target coverage, whereas with VMAT the hotspots were avoided. The patients were treated with the VMAT technique and no acute skin toxicity was observed with either of the patients. CONCLUSIONS: A single isocentre VMAT technique has been implemented clinically for BBI. With the VMAT techniques, the dose delivery was quick and the hotspots in the field overlapping areas were avoided. The PTV dose coverage was superior in VMAT plans when compared with conventional tangential technique plans.

Cite this record

Jan Seppälä, Janne Heikkilä, Kimmo Myllyoja, Kristiina Vuolukka (2015). Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation – A case study. Reports of Practical Oncology & Radiotherapy, 20(5), 398–402. https://doi.org/10.1016/j.rpor.2015.05.011

Copy in another style

Seppälä, J., Heikkilä, J., Myllyoja, K., & Vuolukka, K. (2015). Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation – A case study. Reports of Practical Oncology & Radiotherapy, 20(5), 398–402. https://doi.org/10.1016/j.rpor.2015.05.011
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.