We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Development and Validation of a Reversed-Phase HPLC Method for the Simultaneous Determination of Telmisartan and Its Related Compound B (Positional Isomers) in the Bulk Drug
PeriodicalsChemistry

Development and Validation of a Reversed-Phase HPLC Method for the Simultaneous Determination of Telmisartan and Its Related Compound B (Positional Isomers) in the Bulk Drug

Checking your access to this record.

Abstract & Overview

A simple, selective, accurate, precise and linear RP-HPLC method was developed and validation for Simultaneous determination of Telmisartan and its related Compound B 4ʹ-[(1,7-Dimethyl-2'-propyl[2,5'-bi-1H-benzimidazol]-1'-yl)methyl][1,1'-biphenyl]-2-carboxylic acid; 4'-[(1,7'-dimethyl-2'-propyl-1H,1'H-2,5'-bibenzo[d]imidazol-1'-yl)methyl]biphenyl-2-carboxylic acid; was accomplished in the bulk drug and synthesis for drug and a tablet formulation using a Reversed Phase High Performance liquid chromatography method with UV detection separation was achieved on Inertsil ODS-3V column (150 × 4.6 mm, 5 μm) (GL Science) as stationary phase with binary gradient mode solvent phase A. composed of KH2PO4 (potassium dihydrogen orthophopsphate) buffer (PH adjust =3.5, with triethylamine) and phase B of use filter and degas acetonitrile. The flow rate of the mobile phase was 1.0 mL/min and the total elution time including the column re-equilibration was approximately 30 min. The UV detection wavelength was 246 nm, injection volume was 10 μL and experiments were conducted at 30 °C temperature. The developed method was validated in terms of system suitability, selectivity, linearity, range, precision, accuracy, limits of detection and quantification the for the related compound B, short term and long term stability of the analysts in the prepared solution and robustness, following the ICH guidelines therefore the proposed method was suitable for the simultaneous determination of telmisartan and its related compound B. Keywords: binary gradient, degas acetonitrile, precision, system suitability, telmisartan

Cite this record

Kamlesh M. Patel, Upendra R. Patel, Ashaben D. Patel (2015). Development and Validation of a Reversed-Phase HPLC Method for the Simultaneous Determination of Telmisartan and Its Related Compound B (Positional Isomers) in the Bulk Drug. International Journal of Analytical and Applied Chemistry, 1(2), 12–23. https://library.shubhaarti.com/content/d2aa92ad-6895-4ab6-8415-db88d4ba09f4

Copy in another style

Patel, K. M., Patel, U. R., & Patel, A. D. (2015). Development and Validation of a Reversed-Phase HPLC Method for the Simultaneous Determination of Telmisartan and Its Related Compound B (Positional Isomers) in the Bulk Drug. International Journal of Analytical and Applied Chemistry, 1(2), 12–23. https://library.shubhaarti.com/content/d2aa92ad-6895-4ab6-8415-db88d4ba09f4
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.