We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Computer Science & Information Technology/A dual-role solid calibration strategy for Chang’E-7 LUWA: Onboard CO2 referencing and ground-based H2O/δD validation
PeriodicalsComputer Science & Information Technology

A dual-role solid calibration strategy for Chang’E-7 LUWA: Onboard CO2 referencing and ground-based H2O/δD validation

Checking your access to this record.

Abstract & Overview

Lunar polar water ice is a key target of the Chang’E-7 mission because its abundance, physical state, and origin remain insufficiently constrained. Within the Chang’E-7 multi-payload framework, the LUnar soil Water molecule Analyzer (LUWA) is designed to measure H2O abundance and hydrogen isotopic composition in permanently shadowed regions. Reliable measurements require calibration compatible with high vacuum, low power consumption, limited sealing capability, and restricted heating temperatures, conditions under which conventional gas- and liquid-phase standards are poorly suited. Here, we develop and validate two complementary solid reference materials for LUWA. Vacuum thermogravimetric analysis showed that Ag2CO3 and Cu(OH)2 decompose at approximately 100-120 °C, releasing CO2 and H2O, respectively. Spectroscopic and mass-spectrometric measurements identified the expected dominant signals, with no obvious interfering gaseous species detected within the measured ranges. In the current LUWA implementation, Ag2CO3 was selected as the onboard CO2 reference material for in situ calibration, whereas traceable Cu(OH)2 was developed primarily for ground-based H2O and δD calibration, prototype testing, end-to-end validation, and controlled regolith-simulant experiments. Cu(OH)2 synthesized from precursor waters with known δD values preserved the mean isotopic information of the water source, with absolute differences between precursor-water and solid-derived vapor means within 10‰. Independent Cr-EA/IRMS measurements further supported the isotope-measurement workflow. Beyond its current role, traceable Cu(OH)2 can serve as a solid isotope standard for validating heating, gas release, transfer, pressure measurement, and spectroscopic or mass-spectrometric detection. It also provides a controllable H2O and δD source for regolith simulants with known water contents and for future characterization of adsorption–desorption memory effects, baseline drift, and pressure-dependent isotope response. With further storage, contamination-control, and flight-qualification studies, Cu(OH)2-type materials may support future planetary payloads requiring controlled H2O and hydrogen-isotope references. Together, these results establish a dual-role solid calibration strategy for LUWA.

Cite this record

Rui Chen, Xiang Li, Wenzhen LU, Yi Xu, Nailiang Cao, Hejiu Hui, et al. (2026). A dual-role solid calibration strategy for Chang’E-7 LUWA: Onboard CO2 referencing and ground-based H2O/δD validation. The Innovation Informatics, 2(3), 100062–100062. https://doi.org/10.59717/j.xinn-inform.2026.100062

Copy in another style

Chen, R., Li, X., LU, W., Xu, Y., Cao, N., Hui, H., Yang, Q., Ng, W., Zhang, X., & Chen, K. (2026). A dual-role solid calibration strategy for Chang’E-7 LUWA: Onboard CO2 referencing and ground-based H2O/δD validation. The Innovation Informatics, 2(3), 100062–100062. https://doi.org/10.59717/j.xinn-inform.2026.100062
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.