We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Low Level Determinations of Methyl Methanesulfonate and Ethyl Methanesulfonate Impurities in Emtricitabine Active Pharmaceutical Ingredient by LC/MS/MS using Electrospray Ionization
PeriodicalsChemistry

Low Level Determinations of Methyl Methanesulfonate and Ethyl Methanesulfonate Impurities in Emtricitabine Active Pharmaceutical Ingredient by LC/MS/MS using Electrospray Ionization

Checking your access to this record.

Abstract & Overview

Alkyl methanesulfonates have been highlighted as potential genotoxic impurities (PGIs). A sensitive LC/MS/MS method was developed and validated for the determination of Alkyl methanesulfonate impurities in Emtricitabine API (active pharmaceutical ingredient). LC/MS/MS method on Zorbax SB C(18) column (150 × 4.6 mm i.d.), 3.5 μm, with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode was used. The proposed method was specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.0025 μg/ml to 0.3 μg/ml the correlation coefficient was >0.999 in each case. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.3 μg/g and 0.4 μg/g respectively for both the analytes. Accuracy was observed within 80%-120% for both the analytes. This method can be further extended a good quality control tool for low level quantitation of Alkyl methanesulfonate impurities in other API.

Cite this record

P.R. Kakadiya, T.G. Chandrashekhar, S. Ganguly, D. K. Singh, V. Singh (2011). Low Level Determinations of Methyl Methanesulfonate and Ethyl Methanesulfonate Impurities in Emtricitabine Active Pharmaceutical Ingredient by LC/MS/MS using Electrospray Ionization. Analytical Chemistry Insights, 6, ACI.S6471–ACI.S6471. https://doi.org/10.4137/aci.s6471

Copy in another style

Kakadiya, P., Chandrashekhar, T., Ganguly, S., Singh, D. K., & Singh, V. (2011). Low Level Determinations of Methyl Methanesulfonate and Ethyl Methanesulfonate Impurities in Emtricitabine Active Pharmaceutical Ingredient by LC/MS/MS using Electrospray Ionization. Analytical Chemistry Insights, 6, ACI.S6471–ACI.S6471. https://doi.org/10.4137/aci.s6471
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.