We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Low-Cost, Reproducible Cricothyrotomy Simulation Model for Academic and Independent Learner Use: A Comparative Review and Technical Guide
PeriodicalsMedical Sciences

Low-Cost, Reproducible Cricothyrotomy Simulation Model for Academic and Independent Learner Use: A Comparative Review and Technical Guide

Checking your access to this record.

Abstract & Overview

Abstract Objective To create a novel, low-fidelity, low-cost cricothyrotomy model using readily available materials to simulate key anatomical structures for optimal training. This project aims to provide emergency and otolaryngological providers with the opportunity to practice cricothyrotomies at home using accessible resources. A literature review was conducted to identify gaps in currently available models. Methods Relevant studies were identified through systematic searches of publicly available academic databases: PubMed (PubMed, n.d.) and Google Scholar (Google Scholar, n.d.). Articles were included if they (1) explicitly self-identified their model as a low-cost and/or low-fidelity cricothyrotomy trainer within the title or manuscript, and (2) provided photographic documentation and/or written instructions with a materials list for model construction. Seven parameters were used to assess each model: (1) the use of 3D-printed materials, (2) the use of biologic materials, (3) initial cost, (4) reuse cost, (5) setup time, (6) incorporation of mannequins or artificial skin, and (7) accessibility of materials. Results Eleven articles met the inclusion criteria. Eight of eleven studies (73%) utilized 3D-printed components. Two studies (18%) incorporated porcine skin. Of those reporting initial cost, three of nine studies (33%) exceeded $40. Among studies reporting reuse cost, one of five (20%) exceeded $1.00 per use. The only study reporting setup time (1/1, 100%) described assembly in <20 minutes. Six of eleven studies (55%) incorporated mannequins or artificial skin. Ten of eleven studies (91%) relied on materials that were not widely accessible. Conclusion Most available cricothyrotomy training models rely on 3D-printed or otherwise difficult-to-obtain materials, which limits accessibility for individual practitioners. Guided by these findings, this project introduces a new cricothyrotomy trainer designed to maximize affordability and accessibility while maintaining essential anatomical fidelity.

Cite this record

Katia Castillo, Jacob B. Morgan, John Lipka, Randy Devereaux (2025). Low-Cost, Reproducible Cricothyrotomy Simulation Model for Academic and Independent Learner Use: A Comparative Review and Technical Guide. Academic Medicine & Surgery. https://doi.org/10.62186/001c.144891

Copy in another style

Castillo, K., Morgan, J. B., Lipka, J., & Devereaux, R. (2025). Low-Cost, Reproducible Cricothyrotomy Simulation Model for Academic and Independent Learner Use: A Comparative Review and Technical Guide. Academic Medicine & Surgery. https://doi.org/10.62186/001c.144891
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.