We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Exploring Variability in CT Characterization of Tumors: A Preliminary Phantom Study
PeriodicalsMedical Sciences

Exploring Variability in CT Characterization of Tumors: A Preliminary Phantom Study

Checking your access to this record.

Abstract & Overview

PURPOSE: To explore the effects of computed tomography (CT) slice thickness and reconstruction algorithm on quantification of image features to characterize tumors using a chest phantom. MATERIALS AND METHODS: Twenty-two phantom lesions of known sizes (10 and 20 mm), shapes (spherical, elliptical, lobulated, and spiculated), and densities [-630, -10, and +100 Hounsfield Unit (HU)] were inserted into an anthropomorphic thorax phantom and scanned three times with relocations. The raw data were reconstructed using six imaging settings, i.e., a combination of three slice thicknesses of 1.25, 2.5, and 5 mm and two reconstruction kernels of lung and standard. Lesions were segmented and 14 image features representing lesion size, shape, and texture were calculated. Differences in the measured image features due to slice thickness and reconstruction algorithm were compared using linear regression method by adjusting three confounding variables (size, density, and shape). RESULTS: All 14 features were significantly different between 1.25 and 5 mm slice images. The 1.25 and 2.5 mm slice thicknesses were better than 5 mm for volume, density mean, density SD gray-level co-occurrence matrix (GLCM) energy and homogeneity. As for the reconstruction algorithm, there was no significant difference in uni-dimension, volume, shape index 9, and compactness. Lung reconstruction was better for density mean, whereas standard reconstruction was better for density SD. CONCLUSIONS: CT slice thickness and reconstruction algorithm can significantly affect the quantification of image features. Thinner (1.25 and 2.5 mm) and thicker (5 mm) slice images should not be used interchangeably. Sharper and smoother reconstructions significantly affect the density-based features.

Cite this record

Binsheng Zhao, Yongqiang Tan, Wei Yann Tsai, Lawrence Howard Schwartz, Lin Lü (2014). Exploring Variability in CT Characterization of Tumors: A Preliminary Phantom Study. Translational Oncology, 7(1), 88–93. https://doi.org/10.1593/tlo.13865

Copy in another style

Zhao, B., Tan, Y., Tsai, W. Y., Schwartz, L. H., & Lü, L. (2014). Exploring Variability in CT Characterization of Tumors: A Preliminary Phantom Study. Translational Oncology, 7(1), 88–93. https://doi.org/10.1593/tlo.13865
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.