We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Energy & Renewable Energy/Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT
PeriodicalsEnergy & Renewable Energy

Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT

Checking your access to this record.

Abstract & Overview

The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Low-Voltage Ride-Through (LVRT) capability and staying connected to the grid during the fault occurrence should be considered for the next generation of transformerless PV inverters. In this paper, a study is going underway on the LVRT capability and the Common-Mode Voltage (CMV) in a number of most common transformerless grid-connected PV inverters. In fact, by a comprehensive study on all possible switching combinations and the current paths during the freewheeling period of the selected inverters, the proposed control strategy for performance improvement of the PV inverters under the normal and the LVRT conditions is presented. As a matter of fact, a reconfigurable PWM method is proposed, which makes it possible to switch between two PWM methods and hence provide improved performance of the inverters in the LVRT condition. Finally, the results of simulations in the normal and the LVRT operations to verify the theoretical concepts are indicated.

Cite this record

Mohammad Farhadi‐Kangarlu, Farid Mohammadi (2019). Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT. Journal of operation and automation in power engineering, 7(1), 1–15. https://doi.org/10.22098/joape.2019.4366.1344

Copy in another style

Farhadi‐Kangarlu, M., & Mohammadi, F. (2019). Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT. Journal of operation and automation in power engineering, 7(1), 1–15. https://doi.org/10.22098/joape.2019.4366.1344
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.