We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Experimentally minimized beam emittance from an L -band photoinjector

Checking your access to this record.

Abstract & Overview

High brightness electron sources for linac based free-electron lasers (FELs) are being developed at the Photo Injector Test facility at DESY, Zeuthen site (PITZ). Production of electron bunches with extremely small transverse emittance is the focus of the PITZ scientific program. The photoinjector optimization in 2008--2009 for a bunch charge of 1, 0.5, 0.25, and 0.1 nC resulted in measured emittance values which are beyond the requirements of the European XFEL [S. Rimjaem et al., Nucl. Instrum. Methods Phys. Res., Sect. A 671, 62 (2012)]. Several essential modifications were commissioned in 2010--2011 at PITZ, resulting in further improvement of the photoinjector performance. Significant improvement of the rf gun phase stability is a major contribution in the reduction of the measured transverse emittance. The old TESLA prototype booster was replaced by a new cut disk structure cavity. This allows acceleration of the electron beam to higher energies and supports much higher flexibility for stable booster operation as well as for longer rf pulses which is of vital importance especially for the emittance optimization of low charge bunches. The transverse phase space of the electron beam was optimized at PITZ for bunch charges in the range between 0.02 and 2 nC, where the quality of the beam measurements was preserved by utilizing long pulse train operation. The experimental optimization yielded worldwide unprecedented low normalized emittance beams in the whole charge range studied.

Cite this record

M. Krasilnikov, F. Stephan, G. Asova, H.-J. Grabosch, Matthias Groß, L. Hakobyan, et al. (2012). Experimentally minimized beam emittance from an L -band photoinjector. Physical Review Special Topics - Accelerators and Beams, 15(10), 100701. https://doi.org/10.1103/physrevstab.15.100701

Copy in another style

Krasilnikov, M., Stephan, F., Asova, G., Grabosch, H., Groß, M., Hakobyan, L., Isaev, I., Ivanisenko, Y., Jachmann, L., & Khojoyan, M. (2012). Experimentally minimized beam emittance from an L -band photoinjector. Physical Review Special Topics - Accelerators and Beams, 15(10), 100701. https://doi.org/10.1103/physrevstab.15.100701
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.