We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Percutaneous transcatheter closure of a distorted residual patent ductus arteriosus post surgical ligation using retrograde wiring and femoral arterio-venous loop technique- a case report
PeriodicalsMedical Sciences

Percutaneous transcatheter closure of a distorted residual patent ductus arteriosus post surgical ligation using retrograde wiring and femoral arterio-venous loop technique- a case report

Checking your access to this record.

Abstract & Overview

abstract Small residual left-to-right shunts following surgical ligation of Patent Ductus Arteriosus [PDA] are not common. Percutaneous transcatheter closure of the PDAs, mostly with coils, is the treatment of choice. Large PDAs are closed to prevent CHF, whereas small PDAs are closed to prevent infective endarteritis. Anatomy of the residual duct is distorted by the surgical ligation and may result in a difficult antegrade transcatheter closure. Unfortunately, distortion of anatomy of the duct may not be detected by the two dimensional echocardiogram nor by the descending thoracic aortogram. We describe a challenging retrograde wire assisted device closure of residual PDA in a previously surgically ligated PDA. Objective was to show that retrograde wiring and arteriovenous loop formation may facilitate successful closure of distorted PDAs when antegrade wiring fails. However, there are very few such case reports of closure of residual PDAs by duct occluders using arterio-venous loop technique.

Cite this record

B.G.K. Sudhakar (2018). Percutaneous transcatheter closure of a distorted residual patent ductus arteriosus post surgical ligation using retrograde wiring and femoral arterio-venous loop technique- a case report. IHJ Cardiovascular Case Reports (CVCR), 2(3), 208–210. https://doi.org/10.1016/j.ihjccr.2018.04.008

Copy in another style

Sudhakar, B. (2018). Percutaneous transcatheter closure of a distorted residual patent ductus arteriosus post surgical ligation using retrograde wiring and femoral arterio-venous loop technique- a case report. IHJ Cardiovascular Case Reports (CVCR), 2(3), 208–210. https://doi.org/10.1016/j.ihjccr.2018.04.008
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.