We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Materials Science/Performance Assessment of a Channel Multi-pinhole Collimator for Myocardial Perfusion Imaging with SPECT: A Monte Carlo Simulation
PeriodicalsMaterials Science

Performance Assessment of a Channel Multi-pinhole Collimator for Myocardial Perfusion Imaging with SPECT: A Monte Carlo Simulation

Checking your access to this record.

Abstract & Overview

While the conventional parallel-hole collimators are widely used in myocardial perfusion imaging (MPI) with SPECT, they are suboptimal in balancing the existing sensitivity-resolution compromise. Therefore, multi-pinhole collimation has been proposed to address the problem. In the present study, a channel multi-pinhole collimated SPECT scanner is modeled and then simulated using the GATE Monte Carlo simulation. The multi-pinhole collimator comprises eight apertures. The material, diameter, and height of the apertures were assumed to be varying. A comparison with conventional single-pinhole was also conducted. The results show that increasing the hole diameter leads to degraded spatial resolution for the multi-pinhole collimator. Compared to the single-pinhole, the multi-pinhole collimators suffer from projection overlapping and thus deteriorated spatial resolution. The findings confirm that the channel multi-pinhole collimators outperform the single-pinhole apertures by providing much higher sensitivity at the expense of slightly lower spatial resolution and therefore would be the collimator of choice for MPI with SPECT.

Cite this record

Z. Mohebbi, Elham Saeedzadeh, Hojjat Mahani (2023). Performance Assessment of a Channel Multi-pinhole Collimator for Myocardial Perfusion Imaging with SPECT: A Monte Carlo Simulation. Journal of Nuclear Research and Applications, 3(3), 18–22. https://doi.org/10.24200/jon.2023.1066

Copy in another style

Mohebbi, Z., Saeedzadeh, E., & Mahani, H. (2023). Performance Assessment of a Channel Multi-pinhole Collimator for Myocardial Perfusion Imaging with SPECT: A Monte Carlo Simulation. Journal of Nuclear Research and Applications, 3(3), 18–22. https://doi.org/10.24200/jon.2023.1066
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.