We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Materials Science/Absorption and Desorption of Superabsorbent Polymers for Use in Internally Cured Concrete
PeriodicalsMaterials Science

Absorption and Desorption of Superabsorbent Polymers for Use in Internally Cured Concrete

Checking your access to this record.

Abstract & Overview

Superabsorbent polymers (SAP) have been investigated as an additive for use in the manufacture of internally cured concrete. The ability of SAP to absorb and desorb fluid is important for the design of internally cured concrete mixtures. Internal curing research on lightweight aggregates (LWA) has typically focused on the absorption of water in the LWA internal curing agent. However, when SAP is used, the absorption test should be performed using a pore solution with a defined ionic concentration. To address the effect of the ionic composition of the pore solution on SAP absorption, pore solutions were extracted from fresh cementitious pastes, and their composition was evaluated using X-ray fluorescence. This study characterizes the absorption and desorption of a commercially available SAP, using both simulated and extracted pore solutions with a range of ionic concentrations. The teabag method was implemented to measure the absorption of the SAP. As expected, the absorption of the SAP decreased in solutions with higher ionic concentrations. In addition to studying solutions extracted from ordinary portland cement pastes, the effects of the inclusion of supplementary cementitious materials on the SAP absorption were studied. Results showed that the inclusion of supplementary cementitious materials had a relatively minor impact on the SAP absorption, primarily due to a dilution of the ionic concentration of the pore solution. This article examined the desorption of the SAP in two conditions: a reduction in the ambient relative humidity and after exposure of the SAP to solutions with a higher ionic concentration. It was observed that SAP-containing solutions with a higher ionic concentration had a reduced rate of desorption and a reduced overall desorption at a given relative humidity. In addition, moving the SAP from a solution with a lower ionic concentration to a more highly concentrated solution resulted in desorption. An equation was developed that expresses the SAP absorption as a function of the pH of the soaking solution. The expression was used to predict the desorption of SAP due to an increase in the ionic concentrations in a hydrating system. This equation was used to show that the desorption of SAP due to changes in the pore solution ionic concentration were significant during the first 72 hours. The findings and the techniques used in this study are meant to be used as an example for the characterization of SAP in concrete internal curing applications.

Cite this record

Luca Montanari, Prannoy Suraneni, Marisol Tsui Chang, Chiara Villani, Jason Weiss (2018). Absorption and Desorption of Superabsorbent Polymers for Use in Internally Cured Concrete. Advances in Civil Engineering Materials, 7(4), 547–566. https://doi.org/10.1520/acem20180008

Copy in another style

Montanari, L., Suraneni, P., Chang, M. T., Villani, C., & Weiss, J. (2018). Absorption and Desorption of Superabsorbent Polymers for Use in Internally Cured Concrete. Advances in Civil Engineering Materials, 7(4), 547–566. https://doi.org/10.1520/acem20180008
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.