We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Shear behavior of reinforced concrete beams strengthened utilizing optimized external post-tensioning techniques
PeriodicalsCivil & Construction Engineering

Shear behavior of reinforced concrete beams strengthened utilizing optimized external post-tensioning techniques

Checking your access to this record.

Abstract & Overview

The failure risk of defected reinforced concrete (RC) beams is considered a potential threat. This risk is experimentally identified, numerically analyzed, and thoroughly diminished to enhance structural safety and sustainability to mitigate the potential for structural collapse during construction. This research investigates the efficacy of an external post-tensioning mechanism in enhancing the behavior of defected RC beams lacking shear reinforcement, employing both experimental and numerical approaches. Fourteen RC beams were tested to evaluate the impact of posttensioning force levels and the inclination angle of post-tensioning bars. The study found that regardless of force magnitude or angle, post-tensioning improved the failure characteristics of the non-stirrup beam. The failure mode transitioned from brittle to ductile, resulting in a more advantageous distribution of cracks. Reinforced beams exhibited increased cracking and ultimate loads, with the enhancement more pronounced at higher post-tensioning force levels. Inclined post-tensioning at angles of 75°, 60°, and 45° demonstrated substantial enhancement in cracking and ultimate loads, as well as elastic stiffness. The findings highlighted the superiority of inclined post-tensioning configurations, especially at 60°, for reinforced beams. Moreover, the study revealed a significant increase in absorbed energy with the proposed strengthening system. Additionally, finite element modelling (FEM) was used to replicate the tested beams. FEM accurately predicted the crack development, ultimate capacity, and deformation, aligning well with experimental observations.

Cite this record

Mohamed Ghalla, Alireza Bahrami, Ehab A. Mlybari, Moataz A. Badawi (2025). Shear behavior of reinforced concrete beams strengthened utilizing optimized external post-tensioning techniques. Frontiers of Structural and Civil Engineering, 19(6), 961–979. https://doi.org/10.1007/s11709-025-1185-4

Copy in another style

Ghalla, M., Bahrami, A., Mlybari, E. A., & Badawi, M. A. (2025). Shear behavior of reinforced concrete beams strengthened utilizing optimized external post-tensioning techniques. Frontiers of Structural and Civil Engineering, 19(6), 961–979. https://doi.org/10.1007/s11709-025-1185-4
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.