We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Complications, caused by application of the net implants in the hiatal hernias plasty
PeriodicalsMedical Sciences

Complications, caused by application of the net implants in the hiatal hernias plasty

Checking your access to this record.

Abstract & Overview

Objective. Studying of complications, connected with application of the net implants in patients with large hiatal hernias. Materials and methods. Retrospective investigation was conducted with objective to study complications, connected with application of the net implants in patients with large hiatal hernias, operated in the clinic during period from 2008 to 2018 yr. Of 1168 patients operated on and suffering gastro-esophageal reflux disease as well as hiatal hernias, 817 have had large hernias. In 353 patients with large hernias for strengthening of cruroraphy sutures the net implants were applied. There were used low-weighted implant-net Ultrapro, the composite net Parietex, self-fixating surgical net ProGrip, absorbable net Vicryl, polytetrafluoroethylene net with nitinol carcass, biological net Bio-A. All the patients symptoms were registered, and the quality of life studied. Results. Complications, caused by the net implants impact, were revealed in 17 (1.5%) patients. In all 17 patients the esophageal structuring have occurred due to pronounced cicatrization in region of the net implant installation. In 6 patients dysphagia due to the net ingrowth into esophageal tissue was observed, and in 2 – chronic inflammatory process in place of the net installation. One patient have had small esophageal perforation with restricted mediastinitis. In 3 patients, in whom the polytetrafluoroethylene nets were installed, their migration into esophageal lumen was revealed. Reoperations were done in all 17 patients. In 7 patients the net was removed completely. In 1 patient the net was removed and mediastinum drained. In 3 patients, in whom polytetrafluoroethylene nets have migrated into esophageal lumen, they were removed endoscopically with further installation of special stents. Results of reoperations were estimated as good in 15 patients. In 2 patients after reoperations dysphagia was observed, which needed a second time balloon dilatation and installation of stent in 1 of them. Conclusion. Nonabsorbable nets ought to be applied with high technical accuracy, it is necessary to prevent their contact with the esophagus. Application of the polytetrafluoroethylene nets with nitinol carcass for plasty of large hiatal hernias must be forbidden.

Cite this record

Volodymyr Volodymyrovych Grubnik, Ya. S. Bereznytskyi, V. V. Ilyashenko, Viktor V. Grubnyk, D. V. Korchovyi, Oleksandr Kiosov (2022). Complications, caused by application of the net implants in the hiatal hernias plasty. Klinicheskaia khirurgiia, 89(3-4), 35–39. https://doi.org/10.26779/2522-1396.2022.3-4.35

Copy in another style

Grubnik, V. V., Bereznytskyi, Y. S., Ilyashenko, V. V., Grubnyk, V. V., Korchovyi, D. V., & Kiosov, O. (2022). Complications, caused by application of the net implants in the hiatal hernias plasty. Klinicheskaia khirurgiia, 89(3-4), 35–39. https://doi.org/10.26779/2522-1396.2022.3-4.35
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.