Home/e-Resources/Physics/Validation of the Wii™ Balance Board for countermovement jump height assessment in healthy adults

Checking your access to this record.

Abstract & Overview

BACKGROUND: Vertical jump height assessment is essential for clinical evaluation and monitoring athletic performance. The force platform (Infini-T P6000) is considered the gold standard, whereas the Wii™ Balance Board (WBB) platform is a low-cost and more accessible alternative yet to be validated. AIM: To investigate the reliability and agreement between Infini-T P6000 and WBB in measuring vertical jump height. METHODS: Cross-sectional observational study. Seventy-nine participants performed countermovement jumps on both platforms, in randomized order. Cronbach's alpha was calculated to verify consistency between methods, and intraclass correlation coefficient (ICC:3.1) to verify consistency and absolute agreement, standard error of measurement (SEM), and minimum detectable change (MDC95). Systematic differences between methods were investigated during the ICC analysis using repeated-measures ANOVA (Between Items) and using Bland–Altman analysis. Statistical significance was set at p<0.05. RESULTS: Cronbach’s alpha was 0.923, indicating excellent internal consistency. The ICC ranged from 0.848 to 0.857, confirming high reliability in both definitions. The repeated-measures ANOVA performed during the ICC test revealed significant systematic differences between the methods [F(1,78)=7.514; p=0.008], with mean jump heights of 15.98±5.72 cm (Infini-T P6000) and 16.90±5.45 cm (WBB), resulting in a systematic bias of +0.92 cm favoring WBB, confirmed by Bland–Altman analysis. SEM was 0.86 cm and MDC95≈2.38 cm. INTERPRETATION: WBB shows high reliability in measuring jump height but systematically overestimates values compared to Infini-T P6000. Although the bias is smaller than the MDC95, it compromises direct interchangeability between methods. Standardization of the measurement device in longitudinal assessments or applying a correction offset (Infini-T P6000≈WBB–0.92) is recommended.

Cite this record

Luiz Henrique Cabral Duarte, Larissa Milani Brognoli Sinhorim, Júlio Cezar Rodrigues Da Silva, Giovanna Guolo Coutinho, Maria E. D. França, Iramar Baptistella do Nascimento, et al. (2025). Validation of the Wii™ Balance Board for countermovement jump height assessment in healthy adults. Brazilian Journal of Motor Behavior, 19(1), e511–e511. https://doi.org/10.20338/bjmb.v19i1.511

Copy in another style

Duarte, L. H. C., Sinhorim, L. M. B., Silva, J. C. R. D., Coutinho, G. G., França, M. E. D., Nascimento, I. B. D., Santos, G. G. D., & Schauffert, R. (2025). Validation of the Wii™ Balance Board for countermovement jump height assessment in healthy adults. Brazilian Journal of Motor Behavior, 19(1), e511–e511. https://doi.org/10.20338/bjmb.v19i1.511
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.