We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Data Science & Analytics/Polychromatic pyramid wavefront sensor with MKID technology for high contrast imaging
PeriodicalsData Science & Analytics

Polychromatic pyramid wavefront sensor with MKID technology for high contrast imaging

Checking your access to this record.

Abstract & Overview

The high sensitivity of the pyramid wavefront sensor has made it the preferred sensor in high contrast adaptive optics systems. Future higher contrast systems, like the Extremely Large Telescope’s Planetary Camera System, will require higher performance wavefront sensing. A further performance improvement could be achieved with a polychromatic pyramid wavefront sensor by using additional information over a broader wavelength range. The development of such systems is becoming more feasible with the emergence of new detector technologies such as microwave kinetic inductance detector arrays. These are arrays of superconductor detectors that give a position, arrival time, and measure of the energy for each incident photon. This paper introduces the polychromatic pyramid wavefront sensor concept by defining the technologies and techniques employed and their requirements. A method is developed to track the optical gains, taking advantage of the additional wavelength information, and used to compensate for optical gains within an optimized reconstructor to minimize noise propagation. An overview of expected performance improvement, using end-to-end simulations, is provided using the Keck II adaptive optics system as a reference design. The polychromatic pyramid wavefront sensor was shown to increase the limiting magnitude by 1 to 2 magnitudes, and the contrast by factors of 1.5 to 4, versus single band pyramid wavefront sensors, by sensing over a wavelength range approximately five to ten times broader (800–1800 nm) compared to Z band (152 nm wide) and H band (300 nm wide). Practical design and implementation issues have also been considered.

Cite this record

Aurélie Magniez, Charlotte Z. Bond, Peter L. Wizinowich, Tim Morris, Kieran O’Brien (2026). Polychromatic pyramid wavefront sensor with MKID technology for high contrast imaging. RAS Techniques and Instruments, 5, rzaf064. https://doi.org/10.1093/rasti/rzaf064

Copy in another style

Magniez, A., Bond, C. Z., Wizinowich, P. L., Morris, T., & O’Brien, K. (2026). Polychromatic pyramid wavefront sensor with MKID technology for high contrast imaging. RAS Techniques and Instruments, 5, rzaf064. https://doi.org/10.1093/rasti/rzaf064
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.