Home/e-Resources/Artificial Intelligence & Machine Learning/Accurate Measurements of a Wavelength Drift in High-Temperature Silica-Fiber Bragg Gratings
PeriodicalsArtificial Intelligence & Machine Learning

Accurate Measurements of a Wavelength Drift in High-Temperature Silica-Fiber Bragg Gratings

Checking your access to this record.

Abstract & Overview

Fiber Bragg gratings (FBG) are extensively used to perform high-temperature measurements in harsh environments, however the drift of the characteristic Bragg wavelength affects their long-term stability resulting in an erroneous temperature measurement. Herein we report the most precise and accurate measurements of wavelength drifts available up to date on high-temperature FBGs. The measurements were performed with a set of packaged π-phase-shifted FBGs for high wavelength resolution, in caesium and sodium pressure-controlled heat pipes for stable temperature environment and with a tunable laser for stable wavelength measurements with a 0.1 pm resolution. Using this dataset we outline the experimental caveats that can lead to inconsistent results and confusion in measuring wavelength drifts, namely: influence of packaging; interchangeability of FBGs produced under identical conditions; birefringence of π-phase-shifted FBGs; initial transient behaviour of FBGs at constant temperature and dependence on the previous thermal history of FBGs. In addition, we observe that the wavelength stability of π-phase-shifted gratings at lower temperature is significantly improved upon by annealing at higher temperature. The lowest value of the wavelength drift we obtain is +0.014 pm·h−1 at 600 °C (corresponding to +0.001 °C·h−1) after annealing for 400 h at 1000 °C, the longest annealing time we have tried. The annealing time required to achieve the small drift rate is FBG-specific.

Cite this record

Sergey N. Dedyulin, Elena Timakova, Dan M. Grobnic, Cyril Hnatovsky, Andrew D. W. Todd, Stephen J. Mihailov (2021). Accurate Measurements of a Wavelength Drift in High-Temperature Silica-Fiber Bragg Gratings. Metrology, 1(1), 1–16. https://doi.org/10.3390/metrology1010001

Copy in another style

Dedyulin, S. N., Timakova, E., Grobnic, D. M., Hnatovsky, C., Todd, A. D. W., & Mihailov, S. J. (2021). Accurate Measurements of a Wavelength Drift in High-Temperature Silica-Fiber Bragg Gratings. Metrology, 1(1), 1–16. https://doi.org/10.3390/metrology1010001
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.