We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Estimation of effective dose from CT scanning using dose length product in a Nepalese hospital
PeriodicalsPhysics

Estimation of effective dose from CT scanning using dose length product in a Nepalese hospital

Checking your access to this record.

Abstract & Overview

Keywords: Effective dose, Dose Length Product, Computed Tomography Dose Indexvolume, Dose Reference Level AbstractAim: The aim of this study was to estimate the effective doses from CT scans using DoseLength Product (DLP) in a Nepalese hospital.Materials and methods: This prospective study was conducted in 150 patients above 18years of age who were referred for CT scan of head, chest and abdomen. The CT scan wasperformed on a 128 slice multi detector scanner. All the subjects who met the inclusioncriteria were included in the study. Following the non-contrast imaging phases of the head,chest and abdomen CTDIvol, DLP, kVp and pitch were recorded for each patient from theconsole display of the scanner. The effective dose was calculated for each examination usingDLP which were graphically analyzed and correlated with the age of the patient.Results: The study showed the mean CTDIvol for head, chest and abdomen to be 53.95±4.83mGy, 5.28±1.17 mGy and 11.15±2.71 mGy respectively along with mean DLP to be923.52±71.11 mGycm, 229.32±48.70 mGycm and 517.02±148.32 mGycm respectively. Usingthese values, the mean effective doses were calculated and found to be 1.93±0.14 mSv,3.20±0.68 mSv and 7.75±2.19 mSv respectively.Conclusion: The calculated effective dose values were lower than in other studies for CTexaminations of chest and abdomen while higher or similar for CT examination of head. Theresults of this survey could motivate other researchers to investigate the radiation doses inother hospitals and help establish national diagnostic reference levels.

Cite this record

Pooja Shah (2020). Estimation of effective dose from CT scanning using dose length product in a Nepalese hospital. Radiography Open, 6(1), 56–63. https://doi.org/10.7577/radopen.3565

Copy in another style

Shah, P. (2020). Estimation of effective dose from CT scanning using dose length product in a Nepalese hospital. Radiography Open, 6(1), 56–63. https://doi.org/10.7577/radopen.3565
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.