We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Dentistry/Effect of two Blocking Reverse Taper Preparation Methods on the Internal Fit of CAD/CAM Monolithic Zirconia Crowns (An In-vitro study)
PeriodicalsDentistry

Effect of two Blocking Reverse Taper Preparation Methods on the Internal Fit of CAD/CAM Monolithic Zirconia Crowns (An In-vitro study)

Checking your access to this record.

Abstract & Overview

Background: Limited data is present upon the accuracy of algorithms present inside CAD/CAM software regarding its effect on reverse taper blocking and furthermore on its effect on the internal fit.Aim: To evaluate the effect of two blocking methods of reverse taper preparation (conventional wax blocking and digital software’s algorithm) on the internal fit of CAD/CAM monolithic zirconia crowns and to compare the internal fit between zirconia crowns constructed over blocked preparation and 12º Total Occlusal Convergence (TOC).Material and methods: Thirty CAD/CAM monolithic zirconia crowns were constructed over 3D printed dies. They were divided into three groups, each (n=10) according to the degree of TOC ;12 º, -4 º and -8 º reverse taper. Group II and group III will be further subdivided into 2 sub-groups (n=5) according to the method of reverse taper blocking; A, conventional wax blocking technique and B, digital method. 3D models were created to simulate a reduced upper molar. All dies were scanned to create STL files. Internal fit was assessed with the silicone replica technique. Kruskal-Wallis test was used to compare between the groups. Dunn’s test was used for pair-wise comparisons when Kruskal-Wallis or Friedman’s test is significant. Results: There were no statistically significant difference between internal gap distance measurements of the five groups and between methods.Conclusion: Under the conditions of this study, the internal fit of the zirconia crowns constructed over reverse tapered preparations were within the clinically accepted values (300µ) except for -8o digitally blocked specimen (315.6µ).

Cite this record

Fady Remo Nageeb (2024). Effect of two Blocking Reverse Taper Preparation Methods on the Internal Fit of CAD/CAM Monolithic Zirconia Crowns (An In-vitro study). Journal of Fundamental and Clinical Research, 4(1), 42–57. https://doi.org/10.21608/jfcr.2024.243405.1060

Copy in another style

Nageeb, F. R. (2024). Effect of two Blocking Reverse Taper Preparation Methods on the Internal Fit of CAD/CAM Monolithic Zirconia Crowns (An In-vitro study). Journal of Fundamental and Clinical Research, 4(1), 42–57. https://doi.org/10.21608/jfcr.2024.243405.1060
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.