We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Temperature simulation of microwave ablation based on improved specific absorption rate method compared to phantom measurements
PeriodicalsMedical Sciences

Temperature simulation of microwave ablation based on improved specific absorption rate method compared to phantom measurements

Checking your access to this record.

Abstract & Overview

PURPOSE: To propose an improved specific absorption rate (SAR) computation method by incorporating a thermal conductivity item, develop mathematical simulation models based on the SAR, and enhance the accuracy of temperature simulation for 2450-MHz microwave fields. MATERIALS AND METHODS: Experimental data of 2450-MHz microwave antenna were obtained with a phantom and then new SAR equations were calculated according to Pennes bio-heat transfer equation. Next, the SAR equations were regarded as heating sources and SAR-derived temperature changes were simulated numerically; Finally, temperature measurement results were compared with simulation data to validate the accuracy of the new SAR method. RESULTS: The simulated and measured temperature changes were generally in good agreement for the phantom. According to comparison results, the maximum error was less than 6 °C, the average error was less than 2 °C, and the standard deviation was less than 1 °C. CONCLUSIONS: This new SAR-derived simulation method can significantly simplify the simulation process and improve the prediction accuracy of microwave ablation temperature field.

Cite this record

Hongjian Gao, Shuicai Wu, Xiaoru Wang, Rui Hu, Zhuhuang Zhou, Xuecong Sun (2017). Temperature simulation of microwave ablation based on improved specific absorption rate method compared to phantom measurements. Computer Assisted Surgery, 22(sup1), 9–17. https://doi.org/10.1080/24699322.2017.1378605

Copy in another style

Gao, H., Wu, S., Wang, X., Hu, R., Zhou, Z., & Sun, X. (2017). Temperature simulation of microwave ablation based on improved specific absorption rate method compared to phantom measurements. Computer Assisted Surgery, 22(sup1), 9–17. https://doi.org/10.1080/24699322.2017.1378605
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.