We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Mathematics/Validation of Velocity Measuring Devices in Velocity Based Strength Training
PeriodicalsMathematics

Validation of Velocity Measuring Devices in Velocity Based Strength Training

Checking your access to this record.

Abstract & Overview

To control and monitor strength training with a barbell various systems are on the consumer market. They provide the user with information regarding velocity, acceleration and trajectory of the barbell. Some systems additionally calculate the 1-repetition-maximum (1RM) of exercises and use it to suggest individual intensities for future training. Three systems were tested: GymAware, PUSH Band 2.0 and Vmaxpro. The GymAware system bases on linear position transducers, PUSH Band 2.0 and Vmaxpro base on inertial measurement units. The aim of this paper was to determine the accuracy of the three systems with regard to the determination of the average velocity of each repetition of three barbell strength exercises (squat, barbell rowing, deadlift). The velocity data of the three systems were compared to a Vicon system using linear regression analyses and Bland-Altman-diagrams. In the linear regression analyses the smallest coefficient of determination (R 2 .) in each exercise can be observed for PUSH Band 2.0. In the Bland-Altman diagrams the mean value of the differences in the average velocities is near zero for all systems and all exercises. PUSH Band 2.0 has the largest differences between the Limits of Agreement. For GymAware and Vmaxpro these differences are comparable.

Cite this record

Thorben Menrad, Jürgen Edelmann‐Nusser (2021). Validation of Velocity Measuring Devices in Velocity Based Strength Training. Int. J. Comput. Sci. Sport, 20(1), 106–118. https://doi.org/10.2478/ijcss-2021-0007

Copy in another style

Menrad, T., & Edelmann‐Nusser, J. (2021). Validation of Velocity Measuring Devices in Velocity Based Strength Training. Int. J. Comput. Sci. Sport, 20(1), 106–118. https://doi.org/10.2478/ijcss-2021-0007
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.