We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Increased Sensitivity to Low Concentration Gadolinium Contrast by Optimized Heavily T2-weighted 3D-FLAIR to Visualize Endolymphatic Space
PeriodicalsMedical Sciences

Increased Sensitivity to Low Concentration Gadolinium Contrast by Optimized Heavily T2-weighted 3D-FLAIR to Visualize Endolymphatic Space

Checking your access to this record.

Abstract & Overview

PURPOSE: To increase the sensitivity of 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) to low concentration gadolinium (Gd)-based contrast medium, we optimized sequence parameters on a phantom and evaluated the optimized sequence in patients suspicious for endolymphatic hydrops. MATERIALS AND METHODS: All scans were performed on a 3-tesla magnetic resonance (MR) unit using a 32-channel head coil. We optimized sequence parameters using a phantom filled with diluted Gd and compared the optimized protocol with 3D-FLAIR using conventional turbo spin echo sequence (3D-FLAIR-CONV). Nine patients underwent scanning using the newly optimized sequence and 3D-FLAIR-CONV 4 hours after double-dose administration of intravenous Gd. We subjectively scored separation of endo- and perilymph space and measured contrast-to-noise ratio (CNR) between endo- and perilymph. RESULTS: The optimized sequence in the phantom study consisted of: repetition time, 9000 ms; echo time, 540 ms; inversion time, 2400 ms; low constant readout flip angle, 120 degrees in the later part of the echo train. Image contrast became heavily T(2)-weighted (hT(2)W-3D-FLAIR). In patients, we recognized endolymphatic space for both the cochlea and vestibule significantly better by hT(2)W-3D-FLAIR than 3D-FLAIR-CONV (P<0.01). The mean CNR of the new method was also better than that of 3D-FLAIR-CONV (P<0.01). CONCLUSIONS: The newly optimized hT(2)W-3D-FLAIR was more sensitive than the previous method to low concentration of Gd. Visualization of the endolymphatic space by double-dose administration of intravenous Gd would be more reliable using hT(2)W-3D-FLAIR.

Cite this record

Shinji Naganawa, Hisashi Kawai, Michihiko Sone, Tsutomu Nakashima (2010). Increased Sensitivity to Low Concentration Gadolinium Contrast by Optimized Heavily T2-weighted 3D-FLAIR to Visualize Endolymphatic Space. Magnetic Resonance in Medical Sciences, 9(2), 73–80. https://doi.org/10.2463/mrms.9.73

Copy in another style

Naganawa, S., Kawai, H., Sone, M., & Nakashima, T. (2010). Increased Sensitivity to Low Concentration Gadolinium Contrast by Optimized Heavily T2-weighted 3D-FLAIR to Visualize Endolymphatic Space. Magnetic Resonance in Medical Sciences, 9(2), 73–80. https://doi.org/10.2463/mrms.9.73
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.