We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biomedical Engineering/Design, manufacture, and fatigue analysis of lightweight hip implants
PeriodicalsBiomedical Engineering

Design, manufacture, and fatigue analysis of lightweight hip implants

Checking your access to this record.

Abstract & Overview

BACKGROUND: This study aims to design, analyze and manufacture lightweight hip implants which have sufficient fatigue performance to enable use in total hip arthroplasty (THA). METHODS: The lattice structure was applied on an implant geometry, which is frequently used in THA, to provide a reduction in mass and increase flexibility. The implant surfaces were roughened using semispherical pores to improve the osseointegration. The specimens were manufactured by means of direct metal laser sintering (DMLS) and fatigue tests were performed according to ISO 7206-4:2010. Moreover, fatigue analyses of the designed implants were numerically carried out using the finite element method. RESULTS: The applied lattice structure on implant geometry leads to 15-17% reduction in the masses of implants compared to a solid one. It has also been determined that the lightweight implants show more flexible behavior with increasing pore diameter used on the implant surfaces while keeping the lattice structure geometry constant. The fatigue test and finite element analysis (FEA) results are in reasonable agreement. In addition, additively manufactured solid implants have exhibited similar fatigue performance with one produced by conventional methods. CONCLUSIONS: This paper presents design, analysis, manufacturing and fatigue test processes of lightweight hip implants. The lattice structure and the semispherical pores were applied on a reference implant geometry and they were manufactured by DMLS. The fatigue tests and FEA were performed to evaluate newly designed implant performance. All the implants successfully completed the fatigue tests without any damage.

Cite this record

Yunus Emre Delikanlı, Mehmet Cengiz Kayacan (2019). Design, manufacture, and fatigue analysis of lightweight hip implants. Journal of Applied Biomaterials & Functional Materials, 17(2), 2280800019836830–2280800019836830. https://doi.org/10.1177/2280800019836830

Copy in another style

Delikanlı, Y. E., & Kayacan, M. C. (2019). Design, manufacture, and fatigue analysis of lightweight hip implants. Journal of Applied Biomaterials & Functional Materials, 17(2), 2280800019836830–2280800019836830. https://doi.org/10.1177/2280800019836830
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.