We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Exploring electrochemical impedance spectroscopy for the early diagnosis of Mycobacterium tuberculosis using CFP10:ESAT6 protein detection
PeriodicalsChemistry

Exploring electrochemical impedance spectroscopy for the early diagnosis of Mycobacterium tuberculosis using CFP10:ESAT6 protein detection

Checking your access to this record.

Abstract & Overview

Tuberculosis (TB) was, until SARS-CoV-2 pandemic, the leading cause of death by a single infectious agent contaminating over 10.6 million people with 1.6 million deaths in 2021 worldwide. Herein, we present a proof-of-principle strategy for detecting the recombinant protein CFP10:ESAT6 using an impedimetric immunosensor, which could aid in the diagnosis of tuberculosis. The immunosensor was developed using indium tin oxide electrodes modified by 3-aminopropyltrimethoxysilane monolayer to covalently immobilize anti-CFP10 antibodies. The protein interaction with the antibody recognition platform was directly monitored and measured by cyclic voltammetry and electrochemical impedance spectroscopy, respectively. After the analytical features optimization, a Langmuir isotherm response from 0.5 ng mL-1 to 50 ng mL-1 of pCFP10:ESAT6, limit of detection of 4.80 ng mL-1 and limit of quantification of 15.97 ng mL-1 were achieved, in a 4-hour assay time. Selectivity tests conducted in the presence of DENV NS1 and SARS-CoV-2 Spike proteins at a concentration of 20 ng mL-1, which is one-tenth of the concentration used to optimize pCFP10, indicate that the immunosensor is selective for pCFP10:ESAT6. Additionally, repeatability and reproducibility tests confirm that the immunosensor is suitable, accurate, and selective for detecting the CFP10:ESAT6 protein. The small sample volume required, and short testing time underscore the remarkable capabilities of this immunosensor and its potential for point-of-care screening and diagnostic aid applications.

Cite this record

Luisa Vogado Ribeiro, Juliana Cancino‐Bernardi, Claudia A. Razzino, Thales Rafael Machado, Marco Montero Tuesta, Valtencir Zucolotto (2024). Exploring electrochemical impedance spectroscopy for the early diagnosis of Mycobacterium tuberculosis using CFP10:ESAT6 protein detection. Frontiers in Sensors, 5, 1512936. https://doi.org/10.3389/fsens.2024.1512936

Copy in another style

Ribeiro, L. V., Cancino‐Bernardi, J., Razzino, C. A., Machado, T. R., Tuesta, M. M., & Zucolotto, V. (2024). Exploring electrochemical impedance spectroscopy for the early diagnosis of Mycobacterium tuberculosis using CFP10:ESAT6 protein detection. Frontiers in Sensors, 5, 1512936. https://doi.org/10.3389/fsens.2024.1512936
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.