We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Data Science & Analytics/Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals
PeriodicalsData Science & Analytics

Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals

Checking your access to this record.

Abstract & Overview

Background Ultrasonography (US) is a feasible and accessible method for the measurement of skeletal muscle mass. This technique presents acceptable intra-rater reliability; however, there are a few reports on its inter-rater reliability. Additionally, relative reliability should equally be inspected to determine the presence of systematic errors. Therefore, this study aimed to investigate the intra- and inter-rater reliabilities and absolute reliability of rectus femoris muscle thickness as measured using US. Methods The participants included in our study comprised 12 healthy young men (26.5 ± 3.9 years. Rectus femoris muscle thickness was measured from the right side of the thigh using US by two trained physical therapists. Inter- and intra-rater reliabilities were determined using the intraclass correlation coefficient (ICC) (1, 1) and ICC (2, 1) methods, respectively. Absolute reliability was evaluated using Bland − Altman analysis. Additionally, we calculated the minimal detectable change at the 95% level of confidence (MDC 95 ). Result According to the results of the Bland − Altman analysis, no fixed or proportional errors were present. The ICC (1, 1) was 0.95, and the ICC (2, 1) was 0.70. The MDC 95 values of rectus femoris thickness for the intra- and inter-rater reliabilities were 2.0 mm and 4.3 mm, respectively. Conclusions In our study, intra- and inter-rater reliabilities were measured at “excellent” and “moderate” levels in the healthy individuals based on a previously defined scale. Moreover, we determined the measurement error for quantifying rectus femoris thickness. Therefore, the measurement of rectus femoris thickness using US could be considered applicable in clinical research.

Cite this record

Yosuke Takahashi, Yuji Fujino, Kohei Miura, Ayumi Toida, Tadamitsu Matsuda, Shigeru Makita (2021). Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals. The Ultrasound Journal, 13(1), 21–21. https://doi.org/10.1186/s13089-021-00224-8

Copy in another style

Takahashi, Y., Fujino, Y., Miura, K., Toida, A., Matsuda, T., & Makita, S. (2021). Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals. The Ultrasound Journal, 13(1), 21–21. https://doi.org/10.1186/s13089-021-00224-8
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.