We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Clinical Chemistry and Autoverification: A Path Less Traversed
PeriodicalsChemistry

Clinical Chemistry and Autoverification: A Path Less Traversed

Checking your access to this record.

Abstract & Overview

Aims and background: Autoverification (AV) is an application of artificial intelligence that uses computer-based algorithmically established rules for release of patient reports.This allows effective time management, prevents probable laboratory errors, and ensures consistent results.However, not many labs have adopted AV into practice due to hesitations concerning cost-effectiveness, lack of robust software and informatics support along with dearth of knowledge for its implementation.Additionally, there is scant published literature on AV implementation.This study has been conducted as an attempt to outline benefits of AV and address the existing gaps.Methods: The study was conducted in the Department of Clinical Chemistry of a standalone lab.Autoverification implementation was done in stepwise manner.(i) Test selection and developing algorithms, (ii) Setting-up rules in middleware to prevent release of erroneous results, (iii) User acceptance testing (UAT), (iv) Going-live.Results: Efficacy of AV system was gauged based on following factors.(i) AV passing rate-initial 53.7-85.4% later was achieved with inclusion of more parameters and extension of tolerance limit, (ii) Significant improvement was observed in TAT for both immunoassay (from 88.28 to 97.32%) and routine chemistry (from 82.7 to 95.68%), (iii) decreased error rates as evidenced by reduced number of amended reports, (iv) reduction in staff required for manual verification allowing their utilization for other departmental activities.Conclusion: Implementation of AV by laboratories provides efficient and cost-effective work opportunities with scope for continuous growth.However, it doesn't preclude the need for careful quality control.

Cite this record

Rashmi Rasi Datta, Anurag Bansal (2024). Clinical Chemistry and Autoverification: A Path Less Traversed. Indian Journal of Medical Biochemistry, 28(2), 36–40. https://doi.org/10.5005/jp-journals-10054-0233

Copy in another style

Datta, R. R., & Bansal, A. (2024). Clinical Chemistry and Autoverification: A Path Less Traversed. Indian Journal of Medical Biochemistry, 28(2), 36–40. https://doi.org/10.5005/jp-journals-10054-0233
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.