We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report
PeriodicalsMedical Sciences

Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report

Checking your access to this record.

Abstract & Overview

Background: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequency catheter ablation. Case summary: A 64-year-old female patient with mechanical prosthetic valves underwent atrial fibrillation ablation using the pentaspline pulsed-field ablation catheter. At the end of the uneventful pulmonary vein isolation, an atrial tachycardia depended to the cavotricuspid isthmus occurred. A single pulsed-field application at the cavotricuspid isthmus resulted in right bundle branch block combined with posterior fascicular hemiblock and PR prolongation that resolved spontaneously within 12 h. Discussion: This is the first report of transient conduction disturbances as a complication of cavotricuspid isthmus pulsed-field ablation. Although the underlying mechanism, either single or miscellaneous, was not verified, this case highlights that caution should be taken when the pentaspline pulsed-field ablation catheter is used for cavotricuspid isthmus ablation.

Cite this record

George K. Andrikopoulos, Konstantinos Tampakis, Alexandros Sykiotis, Sokratis Pastromas (2023). Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report. European Heart Journal - Case Reports, 7(8), ytad370–ytad370. https://doi.org/10.1093/ehjcr/ytad370

Copy in another style

Andrikopoulos, G. K., Tampakis, K., Sykiotis, A., & Pastromas, S. (2023). Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report. European Heart Journal - Case Reports, 7(8), ytad370–ytad370. https://doi.org/10.1093/ehjcr/ytad370
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.