We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Robotics & Automation/Improvement of direct power control of DG-Interfaced grid connected Power Converter
PeriodicalsRobotics & Automation

Improvement of direct power control of DG-Interfaced grid connected Power Converter

Checking your access to this record.

Abstract & Overview

Limitation of fossil fuel reserves and environmental pollution resulting from their use, especially in cities, as well as low efficiency of current energy converters lead to the tendency towards the use of more efficient energy converters and renewable energy sources. The use of distributed generation (DG) is one of the appropriate solutions in this regard. There are various techniques provided to control these converters. In this study a new technique of Direct Power Control (DPC) is proposed to connect distributed generation sources to the nationwide grid. This technique not only adds power of distributed generation sources to the grid, but also is capable to compensate the reactive and harmonic power of non-linear loads as well. In this study, Converters’ voltage references for generating compensation current are directly calculated in synchronous rotating coordinate system in each period of sampling; then, a proper pulse width modulation (PWM) generates the used voltages. The proposed DPC technique has some advantages including simple algorithm of fast dynamic as well as fixed switching frequency and small sampling frequency. The performance of the proposed direct control technique is confirmed by simulation results.

Cite this record

Ehsan Talebian Kouchaksaraei, Mehrdad Ahmadi Kamarposhti (2019). Improvement of direct power control of DG-Interfaced grid connected Power Converter. International Journal of Industrial Electronics Control and Optimization, 2(1), 7–16. https://doi.org/10.22111/ieco.2018.25131.1039

Copy in another style

Kouchaksaraei, E. T., & Kamarposhti, M. A. (2019). Improvement of direct power control of DG-Interfaced grid connected Power Converter. International Journal of Industrial Electronics Control and Optimization, 2(1), 7–16. https://doi.org/10.22111/ieco.2018.25131.1039
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.