We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/RSSA Conference: New Advances in CT Dosimetry: The Planar Average Equilibrium Dose
PeriodicalsPhysics

RSSA Conference: New Advances in CT Dosimetry: The Planar Average Equilibrium Dose

Checking your access to this record.

Abstract & Overview

Background: The basis for the current output dose measurement in CT is the computer tomography dose index (CTDI). Modern CT scanners with helical scanning modes, dosage modulation, array detectors, multiple slice planes, or cone-beam irradiation geometries are incompatible with the conventional methods for measuring CT dosimetric performance. The AAPM TG 111 study acknowledged the shortcomings of the CTDI methods and suggested a new method that uses a short conventional ion chamber instead of a pencil chamber and better characterizes the dose profile from contemporary CT scanners. Materials and Methods: Three different anatomical regions (head, chest, and abdomen) of clinical scan sequences were used to build and characterize an in-house phantom design. The equilibrium dosage in our phantom was estimated to determine whether the attenuation of the beam was the same as that of the CTDI phantom. The obtained measurements were compared to those of the CTDI dose estimates made using a conventional pencil chamber. Results: The proposed method allowed the assessment of the equilibrium dosage as well as the accumulation dose for any clinical scan length. By contrast, the CTDI approach can underestimate the dose by 25% to 35% according to our revised methodology Conclusion: The CTDI measurements could no longer be sufficient, and the informed CTDI tends to underestimate the dose provided.

Cite this record

Ahmad Albngali (2023). RSSA Conference: New Advances in CT Dosimetry: The Planar Average Equilibrium Dose. Saudi Journal of Radiology, 1. https://doi.org/10.55038/sjr.v1irssa.117

Copy in another style

Albngali, A. (2023). RSSA Conference: New Advances in CT Dosimetry: The Planar Average Equilibrium Dose. Saudi Journal of Radiology, 1. https://doi.org/10.55038/sjr.v1irssa.117
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.