We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Computer Science & Information Technology/Pseudomonas aeruginosa infections and improper storage conditions influence the performance of 1,3‐β‐ d ‐glucan in diagnosis of invasive fungal infections
PeriodicalsComputer Science & Information Technology

Pseudomonas aeruginosa infections and improper storage conditions influence the performance of 1,3‐β‐ d ‐glucan in diagnosis of invasive fungal infections

Checking your access to this record.

Abstract & Overview

Background The association between 1,3‐β‐d‐glucan (BDG) levels and infections caused by Pseudomonas aeruginosa or Streptococcus pneumoniae, and the stability of BDG under different storage conditions are unclear. Methods Strains of Pseudomonas aeruginosa and S. pneumoniae were grown in medium and human serum. The BDG concentrations in culture supernatants were measured. The specificity and stability of BDG were also evaluated. Results P. aeruginosa produced high levels of BDG in Luria–Bertani medium (>4 × 104 pg/mL) and human serum (527.0 pg/mL), whereas S. pneumoniae produced low levels of BDG in THY medium (175.6 pg/mL) and human serum (78.3 pg/mL). The BDG produced by these two bacteria was specifically degraded by 1,3‐β‐d‐glucanase. BDG was degraded when stored at different temperatures, decreasing by 22.5% and 9.3% at −20°C and −70°C, respectively, for 63 days; by 30.7% at 4°C for 12 days; and by 12.6% and 22.0% at 37°C for 6 and 12 h. Conclusion BDG false‐positivity must be considered in patients with bacteremia caused by P. aeruginosa when diagnosing invasive fungal infection. Human serum samples for the BDG test in medical facilities should be tested as soon as possible or stored at low temperatures before testing.

Cite this record

Zilan Wei, Jie Xu, Yuan Fang, Wendong Fang, Jiahui Wu, Youliang Wang, et al. (2024). Pseudomonas aeruginosa infections and improper storage conditions influence the performance of 1,3‐β‐ d ‐glucan in diagnosis of invasive fungal infections. iLABMED, 2(1), 53–59. https://doi.org/10.1002/ila2.35

Copy in another style

Wei, Z., Xu, J., Fang, Y., Fang, W., Wu, J., Wang, Y., & Chen, S. (2024). Pseudomonas aeruginosa infections and improper storage conditions influence the performance of 1,3‐β‐ d ‐glucan in diagnosis of invasive fungal infections. iLABMED, 2(1), 53–59. https://doi.org/10.1002/ila2.35
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.