We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Ayurveda/Development and validation of a new HPLC method for valproic acid determination in human plasma and its application to a therapeutic drug monitoring study
PeriodicalsAyurveda

Development and validation of a new HPLC method for valproic acid determination in human plasma and its application to a therapeutic drug monitoring study

Checking your access to this record.

Abstract & Overview

The aim of this study was to develop a new, simple and reliable high performance liquid chromatography (HPLC) method for analysis of valproic acid (VPA) in human plasma and apply to it to a therapeutic drug monitoring study. Also, the relationship between plasma-VPA concentrations and the amount of VPA used by patients was aimed to be evaluated. Plasma samples (0.25 mL) were precipitated with the same volume of acetonitrile and after centrifugation, aliquots were applied to a C18 column (250 mm x 4.6 mm). Mobile phase was prepared with phosphate buffer and acetonitrile (47.5:52.5, v/v). The flow-rate was 1.2 mL/min. Accuracy was between -2.9 and 3.2% and precision was ≤6.6%. Method was specific and sensitive with a detection limit of 2.2 µg/mL and the average recovery was 94.3%. Calibration curve was linear (r2>0.9968) from 10 to 150 µg/mL. Plasma-VPA levels of the epileptic patient population (n=33) treated with VPA between 0.5 and 1.5 g/day were also determined. Patient plasma-VPA concentrations ranged from 2.9 to 166.4 µg/g/mL (56.3±38.8). High RSD% (68.8%) was observed in dose-rated plasma-VPA results. Moreover, VPA plasma levels were found to be outside the recommended treatment range in 30.3% of the patients examined. The procedure described was found to be relatively simple, precise, and applicable for routine therapeutic drug monitoring (TDM) especially in neurology clinics or in toxicology reference laboratories. The high standard deviation (SD) observed in the dose depended plasma-VPA values of the volunteers proved the importance of TDM during the use of this drug. The results showed that for rational drug use, it is important to identify individual polymorphisms in the CYP2C9, CYP2A6 and CYP2B6 subtypes responsible for VPA metabolism, and to rearrange drug doses taking these enzyme activities into account.

Cite this record

Emrah Dural, Seniha Çelebi, Aslı Bolayır, Burhanettin Çiğdem (2020). Development and validation of a new HPLC method for valproic acid determination in human plasma and its application to a therapeutic drug monitoring study. Macedonian Pharmaceutical Bulletin, 66(1). https://doi.org/10.33320/maced.pharm.bull.2020.66.01.001

Copy in another style

Dural, E., Çelebi, S., Bolayır, A., & Çiğdem, B. (2020). Development and validation of a new HPLC method for valproic acid determination in human plasma and its application to a therapeutic drug monitoring study. Macedonian Pharmaceutical Bulletin, 66(1). https://doi.org/10.33320/maced.pharm.bull.2020.66.01.001
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.