We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Building Design for Abnormal Loads and Progressive Collapse
PeriodicalsCivil & Construction Engineering

Building Design for Abnormal Loads and Progressive Collapse

Checking your access to this record.

Abstract & Overview

Abstract: A progressive collapse is a structural failure that is initiated by localized structural damage and subsequently develops, as a chain reaction, into a failure that involves a major portion of the structural system. The collapse of the Ronan Point Tower in Canning Town, London, United Kingdom in May, 1968 prompted numerous efforts to develop structural design criteria for progressive collapse resistance. A series of papers and reports appeared in the decade following the Ronan Point collapse, and attempts were made to implement provisions addressing progressive collapse and enhancing general structural integrity in codes and standards. Improved building practices and design procedures to control the likelihood of progressive collapse now are receiving heightened interest by engineers, architects, and standards organizations in the aftermath of the tragedy of September 11, 2001. Advances in the science underlying structural design and the development of structural reliability and risk analysis tools now permit design strategies that would have been considered infeasible 30 years ago. This article provides a critical appraisal of key research products that provide a basis for designing a structural system to withstand local damage without the development of a general structural collapse, and identifies strategies that currently are feasible to implement in the General Design Requirements in ASCE Standard 7, minimum design loads for buildings, and other structures. The article concludes with a discussion of research challenges to further enhancement of design practices, with particular emphasis on needed support for structural engineering analysis and design from advanced computation and information technologies.

Cite this record

Bruce R. Ellingwood, Donald O. Dusenberry (2005). Building Design for Abnormal Loads and Progressive Collapse. Computer-Aided Civil and Infrastructure Engineering, 20(3), 194–205. https://doi.org/10.1111/j.1467-8667.2005.00387.x

Copy in another style

Ellingwood, B. R., & Dusenberry, D. O. (2005). Building Design for Abnormal Loads and Progressive Collapse. Computer-Aided Civil and Infrastructure Engineering, 20(3), 194–205. https://doi.org/10.1111/j.1467-8667.2005.00387.x
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.