We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency-based ion-mobility analyzer with a micromachined drift tube
PeriodicalsChemistry

Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency-based ion-mobility analyzer with a micromachined drift tube

Checking your access to this record.

Abstract & Overview

A radio-frequency-based ion-mobility analyzer with a micromachined drift tube was operated continuously to monitor volatile organic compounds (VOCs) in ambient air inside a building and in an open space near the union of I-10 and I-25 at Las Cruces, New Mexico. Air was drawn directly, without enrichment or preseparation, through the analyzer, which was regulated to 35 °C. The ion source was a photo-discharge lamp at 10.6 eV, providing a preliminary level of selectivity in response to chemicals with low ionization potentials. The compensation voltage was scanned continuously from −40 to +20 V at rates of 60 V/s, providing profiles of ions obtained from VOCs in air. Solvents were detected at 1-ppm levels as fugitive emissions from other experiments under way in the laboratory from 8:00 a.m. to 6:00 p.m. However, patterns in VOC levels from 1 to 5 ppb between 6:00 p.m. and 7:00 a.m. and on weekends was attributed to air exchange between ambient air and the ventilation system of the building. The mobility analyzer results were consistent with VOCs from traffic on major city thoroughfare adjacent to the building. In-field studies near two interstate highways demonstrated that analyzer response could be correlated to traffic patterns and exhibited diurnal trends. These findings demonstrate the concept and practice of micromachined mobility analyzers as continuous monitors for VOCs as airborne vapors in buildings and on site. © 2000 John Wiley & Sons, Inc. Field Analyt Chem Technol 4: 297–308, 2000

Cite this record

Gary A. Eiceman, Erkinjon G. Nazarov, Boris M. Tadjikov, Raanan A. Miller (2000). Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency-based ion-mobility analyzer with a micromachined drift tube. Field Analytical Chemistry & Technology, 4(6), 297–308. https://doi.org/10.1002/1520-6521(2000)4:6%3C297::aid-fact50%3E3.0.co;2-h

Copy in another style

Eiceman, G. A., Nazarov, E. G., Tadjikov, B. M., & Miller, R. A. (2000). Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency-based ion-mobility analyzer with a micromachined drift tube. Field Analytical Chemistry & Technology, 4(6), 297–308. https://doi.org/10.1002/1520-6521(2000)4:6<297::aid-fact50>3.0.co;2-h
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.