We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery
PeriodicalsMedical Sciences

Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery

Checking your access to this record.

Abstract & Overview

BACKGROUND: Robot-assisted minimal access surgery (MAS) reduces blood loss, recovery time, intraoperative and postoperative complications and pain. However, uptake of robotic MAS remains low, suggesting there are barriers to its use. To overcome these barriers, a new surgical robot system, Versius, was developed based on the needs and feedback of surgeons and surgical teams. METHODS: The surgical robot prototype was designed based on observations in the operating room (OR) and previous interviews with surgeons. Formative studies with surgeons and surgical teams were used to refine the prototype design, resulting in modifications to all components, including the arms, instruments, handgrips and surgeon console. Proof-of-concept cadaver studies were used to further optimize its design by assessing its usability during surgical procedures. RESULTS: Feedback led to the development of a novel, mobile design with independent arm carts and surgical console, linked by supported serial or parallel connections, providing maximum flexibility in the OR. Instrument tips were developed based on surgeons' preferred designs and wristed at the tip providing seven degrees of freedom within the patient. Multiple handgrip designs were assessed by surgeons; of these, a 'game controller' design was rated most popular and usable. An open surgical console design allowing multiple working positions was rated highest by surgeons and the surgical teams. CONCLUSIONS: This surgical robot system has been developed using feedback from end users throughout the design process and aims to minimize barriers to robotic MAS uptake. Additionally, these studies demonstrate system success in the surgical procedures it was designed for. The studies reported here, and further studies of the Versius Surgical System, are intended to align with IDEAL (Idea, Development, Exploration, Assessment, Long-term study) Framework guidance.

Cite this record

Luke Hares, Paul Roberts, Keith F Marshall, Mark C. Slack (2019). Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery. BMJ Surgery Interventions & Health Technologies, 1(1), e000019–e000019. https://doi.org/10.1136/bmjsit-2019-000019

Copy in another style

Hares, L., Roberts, P., Marshall, K. F., & Slack, M. C. (2019). Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery. BMJ Surgery Interventions & Health Technologies, 1(1), e000019–e000019. https://doi.org/10.1136/bmjsit-2019-000019
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.