We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Comparative Study of Seismic Analysis of Existing Elevated Reinforced Concrete Intze Water Tank Supported on Frame Staging
PeriodicalsCivil & Construction Engineering

Comparative Study of Seismic Analysis of Existing Elevated Reinforced Concrete Intze Water Tank Supported on Frame Staging

Checking your access to this record.

Abstract & Overview

As known from the very past experiences, elevated water tanks were collapsed or heavily damaged during earth quakes all over the world.These unusual events showed that the supporting system of the elevated tanks has more critical importance than the other structural types of tanks.The main aim of this project is to understand the seismic behavior of the elevated water tank and comparison of various seismic analysis parameters of the elevated reinforced concrete water tank with consideration and modeling of impulsive and convective water masses inside the container in Two Mass Model as per IS: 1893(part 2)-2002.The behavior of elevated water tanks with frame staging pattern is analyzed using from the codes IS 1893 (part 1): 2002 and IS 1893 (part 2): 2002.It can be observed from the analysis that elevated water tank with frame type of staging can perform better by following IS: 1893 (part 2): 2002 because, IS 1893 (part 1): 2002 is only for buildings and is not suitable for liquid retaining structures.The Base Shear and Overturning moments obtained from the code IS 1893 (part 1):2002 are greater than the values obtained from the code IS 1893 (part 2): 2002, this is due to the consideration of single degree of freedom in earlier code.Then finally concluded that in the earlier code the reinforcement is heavy, this will leads to uneconomical and it is considered as one of the disadvantage.From the recent code the base shear and overturning moment is less from that the reinforcement is reduced.It is very necessary to design and analyze the water tank as economical as possible.Finally the results have been presented in the form of graphs and tables.

Cite this record

(2016). Comparative Study of Seismic Analysis of Existing Elevated Reinforced Concrete Intze Water Tank Supported on Frame Staging. International Journal of Constructive Research in Civil Engineering, 2(1). https://doi.org/10.20431/2454-8693.0201002

Copy in another style

Comparative Study of Seismic Analysis of Existing Elevated Reinforced Concrete Intze Water Tank Supported on Frame Staging. (2016). International Journal of Constructive Research in Civil Engineering, 2(1). https://doi.org/10.20431/2454-8693.0201002
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.