We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Mathematics/Successive approximation register maximum power point tracking control with modified PWM-VSI STATCOM for active and reactive power management in a utility grid tied solar photovoltaic system
PeriodicalsMathematics

Successive approximation register maximum power point tracking control with modified PWM-VSI STATCOM for active and reactive power management in a utility grid tied solar photovoltaic system

Checking your access to this record.

Abstract & Overview

Grid-tied solar photovoltaic systems use a PWM-VSI STATCOM to regulate active and reactive power. Due to high reactive power demand, often it has been experienced that there is a decay in reactive power supply which may cause malfunction in the load side equipments. The STATCOM balances power variations caused by solar irradiation and ensures constant DC bus voltage for efficient power conversion and optimal MPPT performance. It also provides dynamic reactive power support, balancing imbalanced loads and filtering harmonics. The modified PWM-VSI controlled by Genetic Algorithm optimized Fractional Order based STATCOM approach enhances dynamic response, improves system efficiency, and integrates with MPPT (SAR) for simultaneous reactive power compensation and extraction. The proposed system ensures grid stability during variable solar generation and outperforms the P&O MPPT controller in active and reactive power management. The proposed system uses a modified PWM-VSI STATCOM controller (FOSTATCOM) to regulate PV system voltage and current waveforms, ensuring grid stability during variable solar generation. The SAR MPPT connected SPV system tied utility grid also outperforms the P&O MPPT controller in active and reactive power management, allowing for 109.1 KW active power supply and 360.2 VAR reactive power supply by integrating modified STATCOM as compared to the P&O MPPT controller with standard PWM-VSI STATCOM which is supplying 108.1 KW and 865.3 VAR.

Cite this record

Nibedita Ghosh, M. A. Asha Rani, Rahul Kumar (2025). Successive approximation register maximum power point tracking control with modified PWM-VSI STATCOM for active and reactive power management in a utility grid tied solar photovoltaic system. Discover Electronics, 2(1), 38. https://doi.org/10.1007/s44291-025-00083-w

Copy in another style

Ghosh, N., Rani, M. A. A., & Kumar, R. (2025). Successive approximation register maximum power point tracking control with modified PWM-VSI STATCOM for active and reactive power management in a utility grid tied solar photovoltaic system. Discover Electronics, 2(1), 38. https://doi.org/10.1007/s44291-025-00083-w
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.