Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy

Checking your access to this record.

Abstract & Overview

INTRODUCTION: To compare the differences in setup errors measured with electronic portal image (EPI) and cone-beam computed tomography (CBCT) in patients undergoing tangential breast radiotherapy (RT). Relationship between setup errors, body mass index (BMI) and breast size was assessed. METHODS: Twenty-five patients undergoing postoperative RT to the breast were consented for this study. Weekly CBCT scans were acquired and retrospectively registered to the planning CT in three dimensions, first using bony anatomy for bony registration (CBCT-B) and again using breast tissue outline for soft tissue registration (CBCT-S). Digitally reconstructed radiographs (DRR) generated from CBCT to simulate EPI were compared to the planning DRR using bony anatomy in the V (parallel to the cranio-caudal axis) and U (perpendicular to V) planes. The systematic (Σ) and random (σ) errors were calculated and correlated with BMI and breast size. RESULTS: = 2.8) were of similar magnitude in the V and U planes. Similarly, the differences in setup errors for CBCT-B and CBCT-S in three dimensions were less than 1 mm. Only CBCT-S setup error correlated with BMI and breast size. CONCLUSIONS: CBCT and EPI show insignificant variation in their ability to detect setup error. These findings suggest no significant differences that would make one modality considered superior over the other and EPI should remain the standard of care for most patients. However, there is a correlation with breast size, BMI and setup error as detected by CBCT-S, justifying the use of CBCT-S for larger patients.

Cite this record

Vikneswary Batumalai, Penny Phan, Callie Choong, Lois Charlotte Holloway, Geoff P. Delaney (2016). Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy. Journal of Medical Radiation Sciences, 63(4), 224–231. https://doi.org/10.1002/jmrs.180

Copy in another style

Batumalai, V., Phan, P., Choong, C., Holloway, L. C., & Delaney, G. P. (2016). Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy. Journal of Medical Radiation Sciences, 63(4), 224–231. https://doi.org/10.1002/jmrs.180
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.