We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/The effect of reduced scan time on response assessment FDG-PET/CT imaging using Deauville score in patients with lymphoma
PeriodicalsPhysics

The effect of reduced scan time on response assessment FDG-PET/CT imaging using Deauville score in patients with lymphoma

Checking your access to this record.

Abstract & Overview

PURPOSE: F]Fluoro-deoxy-glucose positron emission tomography/computed tomography (FDG-PET/CT) is used for response assessment during therapy in Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL). Clinicians report the scans visually using Deauville criteria. Improved performance in modern PET/CT scanners could allow for a reduction in scan time without compromising diagnostic image quality. Additionally, patient throughput can be increased with increasing cost-effectiveness. We investigated the effects of reducing scan time of response assessment FDG-PET/CT in HL and NHL patients on Deauville score (DS) and image quality. METHODS: Twenty patients diagnosed with HL/NHL referred to a response assessment FDG-PET/CT were included. PET scans were performed in list-mode with an acquisition time of 120 s per bed position(s/bp). From PET list-mode data images with full acquisition time of 120 s/bp and shorter acquisition times (90, 60, 45, and 30 s/bp) were reconstructed. All images were assessed by two specialists and assigned a DS. We estimated the possible savings when reducing scan time using a simplified model based on assumed values/costs for our hospital. RESULTS: There were no significant changes in the visually assessed DS when reducing scan time to 90 s/bp, 60 s/bp, 45 s/bp, and 30 s/bp. Image quality of 90 s/bp images were rated equal to 120 s/bp images. Coefficient of variance values for 120 s/bp and 90 s/bp images was significantly < 15%. The estimated annual savings to the hospital when reducing scan time was 8000-16,000 €/scanner. CONCLUSION: Acquisition time can be reduced to 90 s/bp in response assessment FDG-PET/CT without compromising Deauville score or image quality. Reducing acquisition time can reduce costs to the clinic.

Cite this record

Charlotte Hornnes, Annika Loft, Liselotte Højgaard, Flemming Littrup Andersen (2021). The effect of reduced scan time on response assessment FDG-PET/CT imaging using Deauville score in patients with lymphoma. European Journal of Hybrid Imaging, 5(1), 2–2. https://doi.org/10.1186/s41824-021-00096-0

Copy in another style

Hornnes, C., Loft, A., Højgaard, L., & Andersen, F. L. (2021). The effect of reduced scan time on response assessment FDG-PET/CT imaging using Deauville score in patients with lymphoma. European Journal of Hybrid Imaging, 5(1), 2–2. https://doi.org/10.1186/s41824-021-00096-0
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.