We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Life Sciences/Evaluation of an IgG anti-PF4/H chemiluminescent immunoassay in the diagnosis of heparin-induced thrombocytopenia
PeriodicalsLife Sciences

Evaluation of an IgG anti-PF4/H chemiluminescent immunoassay in the diagnosis of heparin-induced thrombocytopenia

Checking your access to this record.

Abstract & Overview

Heparin-induced thrombocytopenia (HIT) is a life-threatening complication of heparin therapy, mediated by immunoglobulin G (IgG) antibodies targeting platelet factor 4/heparin (PF4/H) complexes. Prompt and accurate diagnosis is critical to ensure appropriate treatment and improve outcomes. We aimed to evaluate the performance of the rapid chemiluminescent immunoassay (CLIA) HemosIL AcuStar HIT-IgG (Werfen) for detecting IgG anti-PF4/H antibodies for HIT diagnosis compared with the Zymutest HIA IgG (Hyphen BioMed) enzyme-linked immunosorbent assay (ELISA). This single-center retrospective cohort included all patients with suspected HIT (4Ts score >3). CLIA and ELISA were performed and compared, and results were evaluated against the serotonin-release assay. We included 113 patients with suspected HIT, and HIT was confirmed in 43 (38.1%). Discordant results occurred in 5 patients (4.4%) with confirmed HIT: 3 patients had positive ELISA and negative CLIA, one had both negative ELISA and CLIA, and one had negative ELISA and positive CLIA. CLIA demonstrated a high diagnostic accuracy, with a sensitivity of 90.7% (95% confidence interval [CI], 82.0-99.4) and specificity of 80.0% (95% CI, 70.6-89.3). ELISA showed a sensitivity of 95.3% (95% CI, 89.1-100.0) and negative predictive value of 96.3% (95% CI, 91.3-100.0) compared with 93.3% (95% CI, 87.0-99.6) for CLIA. No significant difference was observed between the 2 tests for sensitivity or specificity. Positive and negative percent agreements were 86.4% (95% CI, 77.7-95.2) and 96.3% (95% CI, 91.3-101.3), respectively. Overall percent agreement was 91.2% (95% CI, 85.9-96.4). This study supports the utility of CLIA as a rapid diagnostic tool for HIT optimizing clinical decision-making and patient management.

Cite this record

Carla Rial, Nicolas Gendron, Christine Le Beller, Shaya Sable, Aurélie Sarthou, Laëtitia Mauge, et al. (2025). Evaluation of an IgG anti-PF4/H chemiluminescent immunoassay in the diagnosis of heparin-induced thrombocytopenia. Blood Vessels Thrombosis & Hemostasis, 2(4), 100084–100084. https://doi.org/10.1016/j.bvth.2025.100084

Copy in another style

Rial, C., Gendron, N., Beller, C. L., Sable, S., Sarthou, A., Mauge, L., Piazza, J., Nili, R., Laney, M., & Présot, I. (2025). Evaluation of an IgG anti-PF4/H chemiluminescent immunoassay in the diagnosis of heparin-induced thrombocytopenia. Blood Vessels Thrombosis & Hemostasis, 2(4), 100084–100084. https://doi.org/10.1016/j.bvth.2025.100084
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.