We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Force–torque intraoperative measurements for femoral shaft fracture reduction
PeriodicalsMedical Sciences

Force–torque intraoperative measurements for femoral shaft fracture reduction

Checking your access to this record.

Abstract & Overview

Background: The minimally invasive technique of closed intramedullary (IM) nailing fixation is currently considered the standard of treatment for the operative management of displaced traumatic fractures of the femur, with fracture reduction and repositioning being the first and most important step of the procedure. Skeletal-muscle traction and alignment of the fracture fragments are always performed as individual components of the reduction and repositioning phase of the procedure.Methods: As use of high traction force and repositioning forces and torques can cause additional soft tissue injury, we developed a sensor-based system to monitor these forces and torques during the treatment of diaphyseal fractures of the femur, including the monitoring of traction forces during the entire procedure, from reduction to IM nail implantation and fixation.Results: Based on a local coordinate system localized at the center of the fracture, maximum forces of 203 N along the medial-lateral (X) axis, 517 N along the anterior–posterior (Y) axis and 505 N along the shaft of the femur (Z-axis) were identified, with maximum torques of 16.4 Nm calculated around Y-axis and 38.3 Nm around X-axis. The pressure between the counteraction post and the perineum was also recorded, with magnitudes as high as 523 N being recorded. Excessive forces were identified and the difference in force–torque magnitudes during different stages of the reduction and fixation procedure were calculated.Conclusion: The measurement system provides surgeons with real-time information which can assist them in performing effective repositioning of fracture fragments within safe margins of applied forces and torques.

Cite this record

Qing Zhu, Bin Liang, XingSong WANG, Xiaogang Sun, Liming Wang (2016). Force–torque intraoperative measurements for femoral shaft fracture reduction. Computer Assisted Surgery, 21(sup1), 37–44. https://doi.org/10.1080/24699322.2016.1240311

Copy in another style

Zhu, Q., Liang, B., WANG, X., Sun, X., & Wang, L. (2016). Force–torque intraoperative measurements for femoral shaft fracture reduction. Computer Assisted Surgery, 21(sup1), 37–44. https://doi.org/10.1080/24699322.2016.1240311
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.